11. Loosen the Clamp Bolt assemblies (2) by turning counter clock wise (CCW).

12. Slide the Carriage assembly to the approximate center of the desired fluid section

and align the shafts. The air motor shaft or fluid section shaft may need to be
moved up or down to allow proper alignment.


13. When the shafts are properly aligned and touching end to end, push the Sleeve up

and install the two coupling Half Shell connectors.


14. Tighten the Clamp Bolts (2), by turning the knobs clock wise (CW).

15. Charge the gel coat accumulator if applicable to the system.

16. Close the ball valve at the bottom of the gel coat filter body.

17. While pressing the pump prime button, adjust the pump regulator to the desired air

pressure.


18. Close the ball valve on the catalyst manifold. Using the catalyst drive hand prime

the catalyst pump pressure and replace the pivot pin into the slide drive assembly.


Adjust the spray pattern as desired. See the “Testing and Adjusting manual” for details.