beautypg.com

Front panel description, Eq1 and eq2, Eq1 only – Lectrosonics EQ1_EQ2 User Manual

Page 5: Eq1 menu options

background image

27 Band Automatic Equalizer

FRONT PANEL DESCRIPTION

LECTROSONICS, INC.

RIO RANCHO, NM U.S.A.

POWER

SAVE

SELECT DOWN

UP

Adjust EQ Curve

Band:

1K

Level:

0

EQ1 Front Panel

LECTROSONICS, INC.

RIO RANCHO, NM U.S.A.

POWER

EQ2 Front Panel

EQ1 and EQ2

POWER SWITCH and LED - Indicates that the EQ1/EQ2 has AC power and is on.

EQ1 Only

LCD DISPLAY - Shows the available menus items for configuring the EQ1.

SAVE Button - Saves the current value of all EQ1 parameters to nonvolatile memory. Used if changes are
made from the front panel which should become permanent. If the SAVE button is not pressed after any
changes, the changes will be lost when the power is removed from the EQ1.

SELECT Button - Moves the active cursor between menu categories.

UP and DOWN Buttons - Increments or decrements the values in the active menu category. If the Up and
Down buttons are both pushed while the power is turned on, the EQ1 will be returned to factory default condition.
Factory defaults are as follows:

1) Stored EQ curve is reset to flat.
2) User Target curves 1-3 are reset to Factory curves 1-3.
3) Pop Suppress system is set to off.
4) LCD display contrast is set to the factory default.
5) Operational mode is set to Local.

EQ1 Menu Options:

EQ1 Address - Allows the LecNet address of the EQ1 to be changed. The factory default address is 131.

Adjust EQ Curve - Allows the cut or boost value of each of the 27 1/3 octave bands to be adjusted. Adjustment
range is +/-15dB.

Adjust Target Curve - Allows any of the three user programmable target curves (U1, U2, or U3) to be adjusted.
Adjustment range for any band is +/-15dB. Note that while no adjustment of the three factory curves (F1, F2,
and F3) is allowed, the factory values may be reviewed using this menu option.

Adjust Target Curve Input Source - Allows the input source associated with each of the user programmable
target curves (U1, U2, or U3) to be chosen. Note that while no change may be made to the input source of the
three factory curves (F1, F2, and F3), the factory values may be reviewed using this menu option.

EQ Status (EQ In/Out) - Bypasses the equalizer and low cut filter of the EQ1. This is useful for A/B compari­
sons between the equalized and unequalized systems.

Low Cut Filter (In/Out) - Bypasses the low cut filter of the EQ1.

Rio Rancho, NM – USA