TUNING Setup Screen

The TUNING setup screen allows

selection of one of four factory set

frequency groups (Groups A through

D), two user programmable frequency groups (Groups

U and V) or the choice to not use groups at all.

Note: User Group Tuning available in units with

firmware version 3.0 and above.

In the four factory set frequency groups, eight frequen-

cies per group are preselected. These frequencies are

chosen to be free of intermodulation products. (See

Frequency Coordination.)
In the two user programmable frequency groups, up to

16 frequencies can be programmed per group.

Note: The Tuning setup screen only selects the

tuning mode (NORMAL or Group Tuning) and

not the operating frequency. Actual operating

frequencies are chosen through the Frequency

Window.

Frequency Window Behavior

If NORMAL tuning mode is selected, the SEL Up and

Down buttons select the operating frequency in single

channel (100 kHz) increments and the MENU+Up and

MENU+Down shortcuts tune in 16 channel (1.6 MHz)

increments.
There are two types of group tuning modes: factory pre-

set groups (Grp A through D) and user programmable

frequency groups (Grp U and V).
When using Group Tuning, a lower case “a, b, c, d, u” or

“v” will be displayed to the immediate left of the trans-

mitter switch settings in the Frequency Window, indicat-

ing which group is selected. If currently tuned frequency

is not in the current tuning group, the indicator will blink.
If a factory tuning group has been selected, pressing

either the SEL Up or Down button will select the nearest

factory selected frequency in that group above or below

the current frequency.

User Programmable Frequency Group Behavior

The user programmable frequency groups work very

similarly to the factory groups with a few exceptions.

The most obvious difference is the ability to add or

remove frequencies from the group. Less obvious is the

behavior of a user programmable frequency group with

only one, or no, entries.
A user programmable frequency group with only one

entry will only display that one frequency regardless

of how many times the SEL Up or Down buttons are

pressed (providing the MENU button is not pressed at

the same time).
A user programmable frequency group with no entries

reverts to non-group-mode behavior, i.e., access is

allowed to all 256 available frequencies in the selected

receiver module’s frequency block. However, once a

frequency has been added to the tuning group, this

behavior changes to group-mode behavior where the

MENU button must be pressed and held while either

the SEL Up or Down buttons are pressed to access

frequencies that are not part of the current tuning group.

Adding/Deleting User Programmable

Frequency Group Entries

Note: Each user programmable frequency group

(“u” or “v”) has separate contents. It is suggested

to review the section titled Frequency Coordination

prior to adding frequencies in order to minimize

potential intermodulation problems.

1. Start from the Frequency Window and verify

that a lower case “u” or “v” is present next to

the transmitter switch settings.

2. While pressing and holding the MENU button

press either the SEL Up or Down button to

move to one of the 256 available frequencies

in the block. Whenever the selection comes

to rest on a frequency that is in the current

group, the group tuning mode indicator (letter

“u” or “v”) will give a steady indication. On

frequencies that are not in the group, the

indicator will blink.

3. To add or remove the displayed frequency

from the group, hold down the MENU button

while pressing and holding the SEL Up button

for about a second. The group tuning mode

indicator will stop blinking to show that the

frequency has been added to the group, or

begin blinking to indicate that the frequency

has been removed from the group.

COMPAT Setup Screen

The

COMPAT setup screen selects

the type of transmitter used with the

UCR411A. The available modes are:

NA 400

North American - Native 400 Series Digital Hybrid mode

NA 100

Lectrosonics 100 Series compatibility

NA 200

Lectrosonics 200 Series compatibility

NA M3

Compatible with certain non-Lectrosonics transmitters*

NA IFB

Compatible with all Lectrosonics IFB transmitters.

NA M6

Compatible with certain non-Lectrosonics transmitters*

NA M7

Compatible with certain non-Lectrosonics transmitters*

EU HBR

European Union - Native 400 Series Digital Hybrid mode

EU 100

European Union - 100 Series compatibility

EU 200

European Union - 200 Series compatibility

EU M3

European Union - Compatible with certain
non-Lectrosonics transmitters*

EU IFB

European Union - Compatible with all Lectrosonics
IFB transmitters.

EU M6

European Union - Compatible with certain
non-Lectrosonics transmitters*

EU M7

European Union - Compatible with certain
non-Lectrosonics transmitters*

*Contact Lectrosonics for a list of compatible transmitters.