Master reset, Unit reset, The idle mode – Controlled Products Systems Group 23-213I User Manual
Page 8: The program mode, The * and # keys
Page 8 American Access Systems / Security Brands, Inc.
MASTER RESET
Follow these steps precisely. If you make an entry error, the unit will ERROR and you will have to start over.
(1).
Disconnect power from the master board
(2).
Reconnect power to the board while holding down the RESET BUTTON
(3).
Release the reset button and enter * * * from the keypad.
The unit will issue a GOODBEEP and the master code will be set back to 1 2 5 1. If the unit was locked in the sleep,
lockA, or lockB mode, the unit will be released and returned to the idle state.
UNIT RESET
(!!! WARNING: ALL ACCESS & FUNCTION CODES WILL BE DELETED FROM MEMORY !!!)
Follow these steps precisely. If you make an entry error, the unit will ERROR and you will have to start over.
(1).
Disconnect power from the master board
(2).
Reconnect power to the board while holding down the RESET BUTTON.
(3).
Release the reset button and enter # * # from the keypad.
(4).
Enter the MASTER CODE from the keypad. (The unit will go into an endless cycle of
beeps).
(5).
Disconnect & Reconnect power to the unit. (The unit will go through the “FIRST TIME
POWER UP” sequence (See “HOOKUP STEPS”, page 5, step C).
THE IDLE MODE
The idle mode is the normal mode of operation. When in this mode the unit sits and waits for data from the keypad.
In this mode you will have approximately 3 seconds between key presses. If this time is exceeded you will receive an
ERROR.
THE PROGRAM MODE
The program mode is the mode of operation in which you will enter, delete, or change your codes or set specific
features of the unit. The program mode is accessed by entering the “MASTER CODE” from the MASTER unit. You will
receive a QUICKBEEP and the yellow LED will come on indicating that you are in the program mode. In this mode you
will have approximately 30 seconds between key presses. If this time is exceeded, you will receive and ERROR and be
exited from the program mode.
THE * AND # KEYS
The * and # keys serve specific functions while in the idle or program mode. The * key is always the clear key and a
double beep will be heard when depressed. You should use this key if you make an entry error. The # key also serves
as a clear key in the idle mode. In the program mode however, it serves as the exit key and will at any time, when
depressed, exit you from the program mode.