Description of surge suppression terminal board – Controlled Products Systems Group ICON26 User Manual
Page 13
12
Icon Page
DESCRIPTION OF SURGE SUPPRESSION TERMINAL BOARD
(+)
(-)
GND
(+)
(-)
GND
(+)
(-)
GND
IN
GND
V-C
V-NO
(+)
(-)
GND
COM
NC
NO
2-NO
2-NC
2-COM
1-NO
1-NC
1-COM
GND
2-IN
1-IN
COM
NC
NO
RS-485 (4)
RS-485 (3)
AUX
OUTPUT RELAYS
AUX
INPUT
12V
AC/DC
RS-485 (2)
FAN
KBRD
LIGHT
AUX 1
RELAY
AUX 2
RELAY
GATE
RELAY
DOOR
RELAY
POWER
POWER IN
TEL LINE IN
POSTAL
SWITCH
EXIT
INPUT
VCR
RELAY
/
RS-485 (1)
GATE
RELAY
DOOR
RELAY
CHASSIS
GROUND
CAMERA
VIDEO
OUT
It is MANDATORY that this unit is properly
grounded. The provided "chassis ground"
wire must be connected to the ground rod.
If unit is not grounded, lightning damage
will occur. Please refer to the owners
manual for proper grounding instructions.
MADE IN USA
AUX OUTPUT RELAYS/AUX INPUT: Inputs can be used for
Postal Lock and/or Exit switch operations.
Auxiliary Input 1-IN activates auxiliary Relay 1
Auxiliary Input 2-IN activates auxiliary Relay 2
POWER IN: 12 Vac to the Entry Phone.
TELEPHONE LINE: Tip and Ring Connection.
GATE RELAY: For use with gate operator to control access
through main vehicular gate.
DOOR RELAY: For allowing access through pedestrian gate
or door.
VIDEO OUT: Camera video output standard BNC cable
connection for use with time lapse VCR. Each time access
is granted, the VCR relay is activated for 5 seconds,
allowing recording of all access to facility.
RS485: Connect to corresponding RS485 terminals (-, +,
GND) of remote security devices.
CHASSIS GROUND: Entry Phone MUST be properly
grounded. Refer to “Grounding the Unit” and
“ Earth Ground Rod Installation” sections.
POSTAL SWITCH/EXIT SWITCH : Connection of a postal
lock or exit switch.
VCR RELAY: For use with time lapse VCR. Each time
access is granted, the VCR relay is activated for 5 seconds,
allowing recording of all access to facility.
CAMERA PORT: For optional camera video input.
FAN LED: Indicates fan is activated.
KEYBOARD LIGHT LED: Indicates keyboard lights have
power.
AUX 1 RELAY LED: Indicates auxiliary 1 relay is activated.
AUX 2 RELAY LED: Indicates auxiliary 2 relay is activated.
GATE RELAY LED: Indicates gate relay is activated.
DOOR RELAY LED: Indicates door relay is activated.
POWER LED: Indicates Phone system has 12 Vac power
present.
1
7
2
8
11
12
13
14
15
16
17
18
3
4
5
6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
10
9
Removable Screw Terminal Connectors for Easy Wiring.
Knockout for
Incoming Wires
POWER IN
12V
AC/DC