beautypg.com

Description of surge suppression terminal board – Controlled Products Systems Group ICON26 User Manual

Page 13

background image

12

Icon Page

DESCRIPTION OF SURGE SUPPRESSION TERMINAL BOARD

(+)

(-)

GND

(+)

(-)

GND

(+)

(-)

GND

IN

GND

V-C

V-NO

(+)

(-)

GND

COM

NC

NO

2-NO

2-NC

2-COM

1-NO

1-NC

1-COM

GND

2-IN

1-IN

COM

NC

NO

RS-485 (4)

RS-485 (3)

AUX

OUTPUT RELAYS

AUX

INPUT

12V

AC/DC

RS-485 (2)

FAN

KBRD

LIGHT

AUX 1

RELAY

AUX 2

RELAY

GATE

RELAY

DOOR

RELAY

POWER

POWER IN

TEL LINE IN

POSTAL

SWITCH

EXIT

INPUT

VCR

RELAY

/

RS-485 (1)

GATE

RELAY

DOOR

RELAY

CHASSIS

GROUND

CAMERA

VIDEO

OUT

It is MANDATORY that this unit is properly
grounded. The provided "chassis ground"
wire must be connected to the ground rod.
If unit is not grounded, lightning damage
will occur. Please refer to the owners
manual for proper grounding instructions.

MADE IN USA

AUX OUTPUT RELAYS/AUX INPUT: Inputs can be used for

Postal Lock and/or Exit switch operations.

Auxiliary Input 1-IN activates auxiliary Relay 1

Auxiliary Input 2-IN activates auxiliary Relay 2

POWER IN: 12 Vac to the Entry Phone.

TELEPHONE LINE: Tip and Ring Connection.

GATE RELAY: For use with gate operator to control access

through main vehicular gate.

DOOR RELAY: For allowing access through pedestrian gate

or door.

VIDEO OUT: Camera video output standard BNC cable

connection for use with time lapse VCR. Each time access

is granted, the VCR relay is activated for 5 seconds,

allowing recording of all access to facility.

RS485: Connect to corresponding RS485 terminals (-, +,

GND) of remote security devices.

CHASSIS GROUND: Entry Phone MUST be properly

grounded. Refer to “Grounding the Unit” and

“ Earth Ground Rod Installation” sections.

POSTAL SWITCH/EXIT SWITCH : Connection of a postal

lock or exit switch.

VCR RELAY: For use with time lapse VCR. Each time

access is granted, the VCR relay is activated for 5 seconds,

allowing recording of all access to facility.

CAMERA PORT: For optional camera video input.

FAN LED: Indicates fan is activated.

KEYBOARD LIGHT LED: Indicates keyboard lights have

power.

AUX 1 RELAY LED: Indicates auxiliary 1 relay is activated.

AUX 2 RELAY LED: Indicates auxiliary 2 relay is activated.

GATE RELAY LED: Indicates gate relay is activated.

DOOR RELAY LED: Indicates door relay is activated.

POWER LED: Indicates Phone system has 12 Vac power

present.

1

7

2

8

11

12

13

14

15

16

17

18

3

4

5

6

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

10

9

Removable Screw Terminal Connectors for Easy Wiring.

Knockout for

Incoming Wires

POWER IN

12V

AC/DC