Description of surge suppression terminal board – Controlled Products Systems Group DIALCODE User Manual
Page 13
DESCRIPTION OF SURGE SUPPRESSION TERMINAL BOARD
12
LC/VF Page
(+)
(-)
GND
(+)
(-)
GND
(+)
(-)
GND
(+)
(-)
GND
DOOR-NO
DOOR-NC
DOOR-C
GATE-NO
GATE-NC
GATE-C
12V
AC/DC
GATE
RELAY
DOOR
RELAY
POWER
POWER
INPUT
GND
INPUT
VCR-NO
VCR-C
TEL
LINE
TIP
RING
RS485 (1)
RS485 (2)
RS485 (3)
RS485 (4)
GATE
RELAY
DOOR
RELAY
CHASSIS
GROUND
POSTAL/EXIT
SW INPUT
VCR
RELAY
TELEPHONE LINE: Tip and Ring Connection.
POWER IN: 12 Vac transformer input.
RS485: Connect to corresponding RS485 terminals (-, +,
GND) of remote security devices.
DOOR RELAY: For allowing access through pedestrian gate or
door.
GATE RELAY: For use with gate operator to control access
through main vehicular gate.
VCR RELAY: For use with Time Lapse VCR. Each time access
is granted, the VCR Relay is activated for 5 seconds, allowing
recording of all access to facility.
POSTAL/EXIT SW INPUT: For allowing postal lock access to
pedestrian gate or door. Activates gate relay using gate strike
time.
CHASSIS GROUND: Entry Phone MUST be properly
grounded. Refer to “Grounding the Unit” and “ Earth Ground
Rod Installation” sections.
POWER LED: Indicates Phone system has 12 Vac power.
GATE RELAY LED: Indicates gate relay is activated.
DOOR RELAY LED: Indicates door relay is activated.
2
4
5
6
7
8
1
1
2
3
4
5
6
7
8
9
10
11
3
3
3
3
9
10
11
It is MANDATORY that this unit is properly
grounded. The provided "chassis ground" wire
must be connected to the ground rod. If unit is
not grounded, lightning damage will occur.
Please refer to the owners manual for proper
grounding instructions.
MADE IN USA
eliteentryphone.com
Knockouts for
Incoming Wires
Removable Screw Terminal Connectors for Easy Wiring.
POWER IN
12V
AC/DC
NOTE: Telephone line used for Telephone Entry System must be a dedicated line.