Installing bd loops in concrete over rebar, Instrucciones español – Controlled Products Systems Group EL24100 User Manual
Page 2
![background image](/manuals/335024/2/background.png)
BD
Loops
|
5362 Bolsa Ave. unit C | Huntington Beach, CA 92649
P: 714 890-1604 | F:714 890-1603 | C: 714 334-6978 | E: [email protected] | www.
BD
Loops
.com
Installing
BD
Loops
in Concrete Over Rebar
When installing
BD
Loops
over rebar make sure to follow these simple instructions:
Determine loop position and lay loop on top of rebar (never below).
Offset the loop from the rebar pattern (see picture below) then use supplied cable ties to secure
loop in place.
Always run the lead-in underneath the rebar. (see picture below)
Run the lead-in 6-
8” under the concrete form.
Run the lead-in in conduit (Schedule 40 or 80 recommended) making sure to glue all PVC joints
with a proper PVC solvent cement.
Scan this or visit:
www.bdloops.com/bdloops_downloadsB.html
In the picture to the right notice how
the “Correct” loop is offset from the
rebar pattern. The loop is coming in
contact with the rebar as little as
possible.
vC4
Visit BDLoops.com to download and
print
Warning Signs
and a
Loop Sign
Off Form
to help protect inductance
loops from the damage that a concrete
crew can cause during a concrete
pour.