beautypg.com

Controlled Products Systems Group 9210-081 User Manual

Plug-in loop detectors, High voltage connection, Dip-switches

background image

Anti-Grounding Plate

TIME

DELA

Y

EXIT

LOOP

LM

T

REVERS

E

LOOP

REV SENSE

OPEN

REV SENSE

CLOS

E

1

ON

23

4

1

ON

23

45

67

8

NC

NO

P8

P7

P6

4404-010

20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

9410

9410

1 2 5 6 11 13A 13B 13E 25

16

17

U

L1 L2/N

B- B+

V

W PE PE

Mode

EPM

Speed

Controller

1.0

PE

SCM series

basic I/O control

115 VAC Convenience Outlets

DO NOT

power up and

cycle the operator until

the “DIP-Switches” and

the “Limit Switches”

have been adjusted.

Damage could occur to

the gate and operator.

T

T

T

T

T

T

T

T

T

Opening direction

using OFF setting.

Opening direction

using ON setting.

EXIT

LOOP

LM

T

REVERS

E

LOOP

REV SENS

E

CLOS

E

P8

P7

P6

440

4-01

0

1

2

4

3

1

2

4

3

1

2

4

3

Ele

ct

ro

ni

c Bo

x

Power safety and opening devices

that require 115 VAC power.

Two 115 VAC Convenience Outlets

Clear Plastic Electronic Box Cover

120 Glasgow Avenue

Inglewood, California 90301

U.S.A.

Model 9200 is intended for installation only on sliding gates used for vehicles.

Pedestrians must be supplied with a separate access opening. For safety and installation instructions,

please refer to the Installation/Owner’s manual.

Copyright 2013 DoorKing, Inc. All rights reserved.

9210-066-E-2-13

Plug-In Loop Detectors

Not included - Refer to the Installation/Owner’s manual AND

Loop Information Manual (available from

www.dkaccess.com

)

for more information on loops and plug-in loop detectors.

Important Note:

DoorKing highly recommends that loops and

loop detectors are installed with this slide gate operator. A loop

detection system will preventing the gate from automatically

opening or closing on a vehicle when it is in the gate’s path.

High Voltage Connection

Tip: It is recommended that a surge suppressor be installed on the high voltage

power lines.

GATE OPERATOR MUST BE PROPERLY GROUNDED!!

DIP-Switches

Limit Switches

1. Opening Direction

2.

ON

3.

ON

4. OFF

5. OFF

6. OFF

7. OFF

8. OFF

1. OFF

2. OFF

3. OFF

4. OFF

Auto-Close Timer

Chassis

Ground

DANGER

HIGH VOLTAGE!

1

ON

23

45

67

8

1

ON

23

4

SW 1 and 2 are Upside-Down on Circuit Board.

1

23

TIME

DELA

Y

A

B

D

C

C

C

B

D

1 ft/s

.5 ft/s

0 ft/s

2 ft/s

1.5 ft/s

Limit LEDs

Plug-In Loop

Detector

Plug-In Loop

Detector

Min Max

Speed

Push

Pu

sh

Lock

-Plat
e

Limit

Nu

t

Limit

Nu

t

Slow

-D

own

Li

m

it

Slow-Down

Limi

t

1A

2A

Par

tial Open

Not Used

1

2

2A

1A

Adjust 1 to 23 sec.

See reverse side

See reverse side to wire main terminal.

1

Limi

t

Switch

2

Limi

t

Switch

Check polarity of Three Phase:

Position the gate half way open.

Give open command and while

gate is opening, activate the

appropriate limit switch with your

finger. Gate should STOP. If it does

not, activate the other limit switch.

If this STOPS the gate, AC power

wires must be changed (Reverse

the connection of any 2 wires and

re-check limits).

Pa

rtia
l Op
en

A

dju

stm

en

t Ra

il

208/230 VAC

THREE Phase

Chassis

Ground

High

Voltage

AC Input

Wire

Hot

115 VAC Output

Hot

Hot

208/230 VAC

SINGLE Phase

Chassis

Ground

High

Voltage

AC Input

Wire

Hot

115 VAC Output

Hot

Use only two legs

of the incoming

3-phase power.

Chassis

Ground

High

Voltage

AC Input

Wire

Hot

115 VAC Output

Neu

115 VAC

SINGLE Phase

White - Neutral

Black - 115 VAC Hot

Green - Chassis

Ground

SW 1

SW 2

A

A

A

Idler

Wheels

Operator Housing

14”

14”

14”

14”

Gate

Operator MUST be parallel to gate!

Chain brackets MUST

align with idler

wheels so chain

stays parallel to gate!

Chain brackets MUST be mounted so

the chain remains the same height as

it is on the idler wheels!

Chain

Bracket

Chain

Bracket

Chain

Bracket

Idler Wheels

Operator Base Plate

Chain

Configuration

Concrete Pad

Concrete Pad

4”

Min. Above Ground

Remove the limit assembly guard.

Remove the 3 locknuts inside the electronic box

to swing box open.

WARNING

MOV

ING

GAT

E CAN

CAU

SE

Oper

ate ga

te on

ly w

hen

gate

area

is in

sigh

t

and

free of

pe

ople

and obs

truct

ion

s.

Do

not a

llow

chi

ldren

to pl

ay in ga

te ar

ea

or ope

rate g

ate.

Do no

t sta

nd in

gate

path

or w

alk thr

oug

h

path

whi

le ga

te is

mov

ing

.

Read o

wne

r’s m

anu

al an

d saf

ety ins

truc

tion

s.

SER

IOUS

INJU

RY O

R DEATH

CLA

SS

CE

RTIF

IED T

O

CAN

/CSA

C22

.2 N

O. 2

47

CON

FOR

MS T

O

ANS

I/UL

-325

VEH

ICUL

AR G

ATE O

PER

ATO

R

HP

5338

2

MOD

EL

SER

IAL

VOLT

S

PHA

SE

AM

PS

60 H

z

MAX

GAT

E LO

AD

Door

King

, Inc

., In

glew

ood,

CA

Limit Assembly Guard

Electronic Bo

x

Tip: Trace the base plate of the operator on a piece

of masonite (Not provided) and make a template to

help locate where the conduit runs will be positioned

in the concrete pad.

Pad depth is determined by soil

conditions and local building codes.

Minimum depth is 18 inches.

Reinforced concrete recommended.

Gain Access Inside Operator

Top

View

Side

View

3/4”conduit

with sweeps

recommended.

Conduit

Area

Conduit

Area

Conduit

Area

1

2

3

Masonite

Template

Not Provided

Condui

t

Cutout

Condui

t

Cutout

Condui

t

Cutout

Concrete pad MUST be level!

1/2

Attach operator to

concrete pad with

twelve (12) 1/2” x 3”

sleeve anchors (not

supplied) after

concrete pad has been

poured and has cured.

18”

20”

Wire

Mesh

23”

28”

1”

1”

4”

4”

Manual

crank in

stored

position.

Manu

al Crank

Access Panel

Conduit suggestions:

High voltage conduit

Low voltage access control device conduit

Reverse loop conduit

Automatic exit loop conduit

Idler wheels

are factory set

in the correct

position.

Remove the chain

knock-outs from

operator housing.

Caution:

Never

attempt to

manually

operate the

9200 until

you have

verified that

power has

been shut-off.

Chain Knock-out

Connect

Chain

to Gate

Chain nut

and chain bolt

should not protrude

past gate frame. The chain

should sag no more than

one (1) inch per 10 feet of

travel. Do not over tighten

the chain.

Chain

Nut

Chain Bolt

Option

2

Master Link

Option

1

Gate

Frame

QUICKSTART “BASIC” GUIDELINES FOR MODEL 9200 “FULL OPEN”: MOUNTED DIRECTLY ON A CONCRETE PAD

Speed Control Knob

On all models but 9210.

All 9200 Models:

DoorKing highly

recommends using the pedestal mounting stand

for gates heavier than 2000 lbs. for a more secure

attachment to a larger and heavier concrete pad.

CAUTION

High Voltage AC input power MUST MATCH

the operator specifications or DAMAGE will

occur and VOID the warranty!

VERIFY Input AC power MATCHES your

specific operator power BEFORE wiring!

With power OFF, push and hold the

lock plate down where shown to

adjust the Open and Close limit nuts.

After adjusting the limit-nuts, be sure

that the lock-plate is engaged in the

slots on the limit-nuts to prevent them

from rotating.

The slow-down limits on all models

but the 9210 will move up or down

3/4 inch.

DO NOT

remove the

slow-down limit assembly from the

3/4 inch slot and re-attach it in the

longer slot on the partial open

adjustment rail to gain further

adjustment.

This will cause mechani-

cal damage to the switch assembly

when the operator is activated.

Turn power ON and activate the gate

operator. Re-adjust the limit nuts as

necessary for full-open and full-close

gate travel. After you are satisfied with

the gate limit settings, the speed

control knob can then be adjusted on

all models but the 9210 to personal

preference.

This manual is related to the following products: