Controlled Products Systems Group 9210-081 User Manual
Plug-in loop detectors, High voltage connection, Dip-switches
Anti-Grounding Plate
TIME
DELA
Y
EXIT
LOOP
LM
T
REVERS
E
LOOP
REV SENSE
OPEN
REV SENSE
CLOS
E
1
ON
23
4
1
ON
23
45
67
8
NC
NO
P8
P7
P6
4404-010
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
9410
9410
1 2 5 6 11 13A 13B 13E 25
16
17
U
L1 L2/N
B- B+
V
W PE PE
Mode
EPM
Speed
Controller
1.0
PE
SCM series
basic I/O control
115 VAC Convenience Outlets
DO NOT
power up and
cycle the operator until
the “DIP-Switches” and
the “Limit Switches”
have been adjusted.
Damage could occur to
the gate and operator.
T
T
T
T
T
T
T
T
T
Opening direction
using OFF setting.
Opening direction
using ON setting.
EXIT
LOOP
LM
T
REVERS
E
LOOP
REV SENS
E
CLOS
E
P8
P7
P6
440
4-01
0
1
2
4
3
1
2
4
3
1
2
4
3
Ele
ct
ro
ni
c Bo
x
Power safety and opening devices
that require 115 VAC power.
Two 115 VAC Convenience Outlets
Clear Plastic Electronic Box Cover
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Model 9200 is intended for installation only on sliding gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions,
please refer to the Installation/Owner’s manual.
Copyright 2013 DoorKing, Inc. All rights reserved.
9210-066-E-2-13
Plug-In Loop Detectors
Not included - Refer to the Installation/Owner’s manual AND
Loop Information Manual (available from
www.dkaccess.com
)
for more information on loops and plug-in loop detectors.
Important Note:
DoorKing highly recommends that loops and
loop detectors are installed with this slide gate operator. A loop
detection system will preventing the gate from automatically
opening or closing on a vehicle when it is in the gate’s path.
High Voltage Connection
Tip: It is recommended that a surge suppressor be installed on the high voltage
power lines.
GATE OPERATOR MUST BE PROPERLY GROUNDED!!
DIP-Switches
Limit Switches
1. Opening Direction
2.
ON
3.
ON
4. OFF
5. OFF
6. OFF
7. OFF
8. OFF
1. OFF
2. OFF
3. OFF
4. OFF
Auto-Close Timer
Chassis
Ground
DANGER
HIGH VOLTAGE!
1
ON
23
45
67
8
1
ON
23
4
SW 1 and 2 are Upside-Down on Circuit Board.
1
23
TIME
DELA
Y
A
B
D
C
C
C
B
D
1 ft/s
.5 ft/s
0 ft/s
2 ft/s
1.5 ft/s
Limit LEDs
Plug-In Loop
Detector
Plug-In Loop
Detector
Min Max
Speed
Push
Pu
sh
Lock
-Plat
e
Limit
Nu
t
Limit
Nu
t
Slow
-D
own
Li
m
it
Slow-Down
Limi
t
1A
2A
Par
tial Open
Not Used
1
2
2A
1A
Adjust 1 to 23 sec.
See reverse side
See reverse side to wire main terminal.
1
Limi
t
Switch
2
Limi
t
Switch
Check polarity of Three Phase:
Position the gate half way open.
Give open command and while
gate is opening, activate the
appropriate limit switch with your
finger. Gate should STOP. If it does
not, activate the other limit switch.
If this STOPS the gate, AC power
wires must be changed (Reverse
the connection of any 2 wires and
re-check limits).
Pa
rtia
l Op
en
A
dju
stm
en
t Ra
il
208/230 VAC
THREE Phase
Chassis
Ground
High
Voltage
AC Input
Wire
Hot
115 VAC Output
Hot
Hot
208/230 VAC
SINGLE Phase
Chassis
Ground
High
Voltage
AC Input
Wire
Hot
115 VAC Output
Hot
Use only two legs
of the incoming
3-phase power.
Chassis
Ground
High
Voltage
AC Input
Wire
Hot
115 VAC Output
Neu
115 VAC
SINGLE Phase
White - Neutral
Black - 115 VAC Hot
Green - Chassis
Ground
SW 1
SW 2
A
A
A
Idler
Wheels
Operator Housing
14”
14”
14”
14”
Gate
Operator MUST be parallel to gate!
Chain brackets MUST
align with idler
wheels so chain
stays parallel to gate!
Chain brackets MUST be mounted so
the chain remains the same height as
it is on the idler wheels!
Chain
Bracket
Chain
Bracket
Chain
Bracket
Idler Wheels
Operator Base Plate
Chain
Configuration
Concrete Pad
Concrete Pad
4”
Min. Above Ground
Remove the limit assembly guard.
Remove the 3 locknuts inside the electronic box
to swing box open.
WARNING
MOV
ING
GAT
E CAN
CAU
SE
Oper
ate ga
te on
ly w
hen
gate
area
is in
sigh
t
and
free of
pe
ople
and obs
truct
ion
s.
Do
not a
llow
chi
ldren
to pl
ay in ga
te ar
ea
or ope
rate g
ate.
Do no
t sta
nd in
gate
path
or w
alk thr
oug
h
path
whi
le ga
te is
mov
ing
.
Read o
wne
r’s m
anu
al an
d saf
ety ins
truc
tion
s.
SER
IOUS
INJU
RY O
R DEATH
CLA
SS
CE
RTIF
IED T
O
CAN
/CSA
C22
.2 N
O. 2
47
CON
FOR
MS T
O
ANS
I/UL
-325
VEH
ICUL
AR G
ATE O
PER
ATO
R
HP
5338
2
MOD
EL
SER
IAL
VOLT
S
PHA
SE
AM
PS
60 H
z
MAX
GAT
E LO
AD
Door
King
, Inc
., In
glew
ood,
CA
Limit Assembly Guard
Electronic Bo
x
Tip: Trace the base plate of the operator on a piece
of masonite (Not provided) and make a template to
help locate where the conduit runs will be positioned
in the concrete pad.
Pad depth is determined by soil
conditions and local building codes.
Minimum depth is 18 inches.
Reinforced concrete recommended.
Gain Access Inside Operator
Top
View
Side
View
3/4”conduit
with sweeps
recommended.
Conduit
Area
Conduit
Area
Conduit
Area
1
2
3
Masonite
Template
Not Provided
Condui
t
Cutout
Condui
t
Cutout
Condui
t
Cutout
Concrete pad MUST be level!
1/2
Attach operator to
concrete pad with
twelve (12) 1/2” x 3”
sleeve anchors (not
supplied) after
concrete pad has been
poured and has cured.
18”
20”
Wire
Mesh
23”
28”
1”
1”
4”
4”
Manual
crank in
stored
position.
Manu
al Crank
Access Panel
Conduit suggestions:
•
High voltage conduit
•
Low voltage access control device conduit
•
Reverse loop conduit
•
Automatic exit loop conduit
Idler wheels
are factory set
in the correct
position.
Remove the chain
knock-outs from
operator housing.
Caution:
Never
attempt to
manually
operate the
9200 until
you have
verified that
power has
been shut-off.
Chain Knock-out
Connect
Chain
to Gate
Chain nut
and chain bolt
should not protrude
past gate frame. The chain
should sag no more than
one (1) inch per 10 feet of
travel. Do not over tighten
the chain.
Chain
Nut
Chain Bolt
Option
2
Master Link
Option
1
Gate
Frame
QUICKSTART “BASIC” GUIDELINES FOR MODEL 9200 “FULL OPEN”: MOUNTED DIRECTLY ON A CONCRETE PAD
Speed Control Knob
On all models but 9210.
All 9200 Models:
DoorKing highly
recommends using the pedestal mounting stand
for gates heavier than 2000 lbs. for a more secure
attachment to a larger and heavier concrete pad.
CAUTION
High Voltage AC input power MUST MATCH
the operator specifications or DAMAGE will
occur and VOID the warranty!
VERIFY Input AC power MATCHES your
specific operator power BEFORE wiring!
With power OFF, push and hold the
lock plate down where shown to
adjust the Open and Close limit nuts.
After adjusting the limit-nuts, be sure
that the lock-plate is engaged in the
slots on the limit-nuts to prevent them
from rotating.
The slow-down limits on all models
but the 9210 will move up or down
3/4 inch.
DO NOT
remove the
slow-down limit assembly from the
3/4 inch slot and re-attach it in the
longer slot on the partial open
adjustment rail to gain further
adjustment.
This will cause mechani-
cal damage to the switch assembly
when the operator is activated.
Turn power ON and activate the gate
operator. Re-adjust the limit nuts as
necessary for full-open and full-close
gate travel. After you are satisfied with
the gate limit settings, the speed
control knob can then be adjusted on
all models but the 9210 to personal
preference.