Indications – CTEK ZAFIR 100 User Manual
Page 8

INDICATIONS
Indication Description
0
Error mode, the charger suspends the charging / voltage maintenance. See further
description below.
1 Start
mode.
2
Bulk charging, maximum voltage.
3
Absorption charging, voltage limited to chosen voltage.
4
Pulse maintenance charging
5
Supply mode, fixed output voltage, no counter voltage requirement.
6 Recond
charging
A POWER-ON
B
Mode ”NORMAL” (14.4V)
C
Mode ”SNOWFLAKE” (14.7V)
D
Mode ”SUPPLY” (13.6V)
E
Mode ”RECOND” (15.7V, 1.5A 0.5–4h)
Error mode
The charger enters error mode before start in the following situations:
The battery is connected with poles reversed to the charger's terminals.
The terminals on the charger are short-circuited.
Error mode before start is reset by removing the error situation. The charger restarts in the
latest selected mode.
The charger enters steady error mode in the following situations:
The charger’s analysis function has interrupted charging.
The charger is overloaded in Supply mode.
The charger has been in start mode longer than maximum time.
Steady error mode is acknowledged/reset by pressing the ”MODE” button. The charger restarts