Maintenance charging - float (Lamp 4) 
During the first 10 days of maintenance charging the battery is maintained with constant volt-
age, 27.2V. Float-maintenance is indicated by lamp 4.
Maintenance charging - pulse (Lamp 4) 
State of charge varies between 95% and 100%. The battery receives a pulse when the voltage 
sinks, keeping the battery in good shape when it is not being used. The charger can be con-
nected for months at a time. 
If the battery is charged and/or the battery’s terminal voltage drops, the charger starts a charge 
pulse until the voltage has reached the preset level, 28.8V or 29.4V. The charge pulse is then 
interrupted and the cycle is repeated as long as the charger is in pulse maintenance phase. If 
the terminal voltage drops even lower, the charger automatically reverts to the beginning of the 
charging curve. Pulse maintenance phase is indicated by lamp 4. If possible, check the water 
level in the battery. If an external load is connected, the charger will return to the Maintenance 
charge – float step.
Chosen mode: ”RECOND”
MULTI XT 4000 has a Recond mode which is used to recondition a battery that has been 
severely discharged. The battery is first charged using the mode ”NORMAL”. When the analysis 
phase is complete, the charger begins reconditioning the battery by providing a constant 
current of 0.9A and a maximum voltage of 31.4V. After 0.5–4 hours, the battery is completely 
reconditioned and the charger goes into pulse maintenance. The battery is ready to be used, or 
store it with pulse maintenance active until you are ready to use the battery. Recond is indicated 
by lamp D and lamp 5. Note that the recond phase begins with a normal charging and that the 
charger therefore will indicate the charging phases according to the descriptions above first. 
Lamp 5 is first lit when the reconditioning begins. 
TEMPERATURE PROTECTION
MULTI XT 4000 is protected from being overheated. The power will be reduced if the ambient 
temperature is raised.
MAINTENANCE
The charger is maintenance free. Note that disassembly of the charger is not permitted and 
will void the warranty. If the power cord is damaged, the charger must be left to the reseller for 
maintenance. The case can be cleaned with a soft damp cloth and mild cleanser. The charger 
should be disconnected from the power while cleaning.
EQUIPMENT
MULTI XT 4000 is delivered with a set of battery leads with battery pole clamps and a set of 
battery leads with eyelet terminals.
WARRANTY
CTEK SWEDEN AB, Rostugnsvägen 3, SE-776 70 VIKMANSHYTTAN, SWEDEN provides 
a limited warranty to the original purchaser of this product. This limited warranty is not 
transferable. The unit is warranted against defective workmanship or materials for 
2 years
from the date of purchase. The customer must return the product together with the original 
purchase receipt to the place of purchase. This warranty is void if the unit is handled carelessly, 
opened or repaired by anyone other than CTEK SWEDEN AB or its authorized representative. 
CTEK SWEDEN AB makes no warranty other than this limited warranty and expressly excludes 