Program description – CTEK MXS 15000 User Manual
Page 3

PROGRAM DESCRIPTION
C
ur
re
nt (
Am
pe
re
s) V
ol
ta
ge (
Vo
lts
)
Desulphation
Soft Start
Bulk
Absorption
Analysis
Recond
Float
Pulse
Recovers a
sulphated battery
Tests the battery
condition
Bulk charge
Peak charge with
minimal fluid loss
Tests whether the
battery retains
the energy
Reconditioning of
a drained battery
Maintenance for
maximum
performance
Maintenance for
maximum
battery life
MULTI XS 15000 PARAMETERS
MODE Desulphation
Soft Start
Bulk
Absorption
Analysis
Recond
Float
Pulse
NORMAL
or
RECOND
YES
Max 15A for 4h until
the voltage reaches
12V.
15A for max 20h.
14.4V until 4h after
the current dropped
to 2.5A, max 12h.
Warning indication
if voltage drops to
12.0V in 3 minutes.
Max 15.8V and 3A
for 4h for deeply
discharged
batteries.Otherwise
for 30 minutes (only
in Recond mode).
13.6V with max 15A
for max 10 days.
Pulse start at 12.9V,
max voltage 14.4V.
SUPPLY
13.6V max 15A.
20
01
07
32
A