beautypg.com

Charging programs and options combinations – CTEK MXS 5.0 User Manual

Page 3

background image

EN

EN • 5

CHARGING PROGRAMS AND OPTIONS COMBINATIONS

DESULPHATION

SOFT START

BULK

ABSORPTION

ANALYSE

RECOND

FLOAT

PULSE

Current (A) Voltage (V)

15.8V

0.8A until 12.6V

Increasing voltage to

14.4V. 0.8A

Declining current

14.4V

Checks if voltage

drops to 12V

13.6V

0.8A

12.7V–14.4V

0.8–0.3A

+

AGM

15.8V

0.8A until 12.6V

Increasing voltage to

14.7V. 0.8A

Declining current

14.7V

Checks if voltage

drops to 12V

13.6V

0.8A

12.7V–14.7V

0.8–0.3A

+

RECOND

15.8V

0.8A until 12.6V

Increasing voltage to

14.4V. 0.8A

Declining current

14.4V

Checks if voltage

drops to 12V

Max 15.8V

0.3A

13.6V

0.8A

12.7V–14.4V

0.8–0.3A

+

AGM

+

RECOND

15.8V

0.8A until 12.6V

Increasing voltage to

14.7V. 0.8A

Declining current

14.7V

Checks if voltage

drops to 12V

Max 15.8V

0.3A

13.6V

0.8A

12.7V–14.7V

0.8–0.3A

15.8V

5A until 12.6V

Increasing voltage to

14.4V. 5A

Declining current

14.4V

Checks if voltage

drops to 12V

13.6V

5A

12.7V–14.4V

5–2.5A

+

AGM

15.8V

5A until 12.6V

Increasing voltage to

14.7V. 5A

Declining current

14.7V

Checks if voltage

drops to 12V

13.6V

5A

12.7V–14.7V

5–2.5A

+

RECOND

15.8V

5A until 12.6V

Increasing voltage to

14.4V. 5A

Declining current

14.4V

Checks if voltage

drops to 12V

Max 15.8V

1.8A

13.6V

5A

12.7V–14.4V

5–2.5A

+

AGM

+

RECOND

15.8V

5A until 12.6V

Increasing voltage to

14.7V. 5A

Declining current

14.7V

Checks if voltage

drops to 12V

Max 15.8V

1.8A

13.6V

5A

12.7V–14.7V

5–2.5A

Time limit:

Max 8h

Max 20h

Max 8h

3 minutes

2h or 6h

10days

Charge cycle restarts

if voltage drops

Charge cycle restarts

if voltage drops