Charging programs and options combinations – CTEK MXS 5.0 User Manual
Page 3
EN
EN • 5
CHARGING PROGRAMS AND OPTIONS COMBINATIONS
DESULPHATION
SOFT START
BULK
ABSORPTION
ANALYSE
RECOND
FLOAT
PULSE
Current (A) Voltage (V)
15.8V
0.8A until 12.6V
Increasing voltage to
14.4V. 0.8A
Declining current
14.4V
Checks if voltage
drops to 12V
13.6V
0.8A
12.7V–14.4V
0.8–0.3A
+
AGM
15.8V
0.8A until 12.6V
Increasing voltage to
14.7V. 0.8A
Declining current
14.7V
Checks if voltage
drops to 12V
13.6V
0.8A
12.7V–14.7V
0.8–0.3A
+
RECOND
15.8V
0.8A until 12.6V
Increasing voltage to
14.4V. 0.8A
Declining current
14.4V
Checks if voltage
drops to 12V
Max 15.8V
0.3A
13.6V
0.8A
12.7V–14.4V
0.8–0.3A
+
AGM
+
RECOND
15.8V
0.8A until 12.6V
Increasing voltage to
14.7V. 0.8A
Declining current
14.7V
Checks if voltage
drops to 12V
Max 15.8V
0.3A
13.6V
0.8A
12.7V–14.7V
0.8–0.3A
15.8V
5A until 12.6V
Increasing voltage to
14.4V. 5A
Declining current
14.4V
Checks if voltage
drops to 12V
13.6V
5A
12.7V–14.4V
5–2.5A
+
AGM
15.8V
5A until 12.6V
Increasing voltage to
14.7V. 5A
Declining current
14.7V
Checks if voltage
drops to 12V
13.6V
5A
12.7V–14.7V
5–2.5A
+
RECOND
15.8V
5A until 12.6V
Increasing voltage to
14.4V. 5A
Declining current
14.4V
Checks if voltage
drops to 12V
Max 15.8V
1.8A
13.6V
5A
12.7V–14.4V
5–2.5A
+
AGM
+
RECOND
15.8V
5A until 12.6V
Increasing voltage to
14.7V. 5A
Declining current
14.7V
Checks if voltage
drops to 12V
Max 15.8V
1.8A
13.6V
5A
12.7V–14.7V
5–2.5A
Time limit:
Max 8h
Max 20h
Max 8h
3 minutes
2h or 6h
10days
Charge cycle restarts
if voltage drops
Charge cycle restarts
if voltage drops