Charging programs and options combinations – CTEK MXS 5.0 CHECK User Manual
Page 5
EN • 7
EN
CHARGING PROGRAMS ANd OPTIONS COMBINATIONS
dESULPHATION
SOFT START
BULK
ABSORPTION
ANALYSE
RECONd
FLOAT
PULSE
C
ur
re
nt (
A
) V
ol
ta
ge (
V)
15.8V
0.8A until 12.6V
Increasing voltage to
14.4V. 0.8A
Declining current
14.4V
Checks if voltage
drops to 12V
13.6V
0.8A
12.7V–14.4V
0.8–0.4A
+
15.8V
0.8A until 12.6V
Increasing voltage to
14.7V. 0.8A
Declining current
14.7V
Checks if voltage
drops to 12V
13.6V
0.8A
12.7V–14.7V
0.8–0.4A
+
RECOND
15.8V
0.8A until 12.6V
Increasing voltage to
14.4V. 0.8A
Declining current
14.4V
Checks if voltage
drops to 12V
Max 15.8V
0.3A
13.6V
0.8A
12.7V–14.4V
0.8–0.4A
+
+
RECOND
15.8V
0.8A until 12.6V
Increasing voltage to
14.7V. 0.8A
Declining current
14.7V
Checks if voltage
drops to 12V
Max 15.8V
0.3A
13.6V
0.8A
12.7V–14.7V
0.8–0.4A
15.8V
5A until 12.6V
Increasing voltage to
14.4V. 5A
Declining current
14.4V
Checks if voltage
drops to 12V
13.6V
5A
12.7V–14.4V
5–2A
+
15.8V
5A until 12.6V
Increasing voltage to
14.7V. 5A
Declining current
14.7V
Checks if voltage
drops to 12V
13.6V
5A
12.7V–14.7V
5–2A
+
RECOND
15.8V
5A until 12.6V
Increasing voltage to
14.4V. 5A
Declining current
14.4V
Checks if voltage
drops to 12V
Max 15.8V
1.5A
13.6V
5A
12.7V–14.4V
5–2A
+
+
RECOND
15.8V
5A until 12.6V
Increasing voltage to
14.7V. 5A
Declining current
14.7V
Checks if voltage
drops to 12V
Max 15.8V
1.5A
13.6V
5A
12.7V–14.7V
5–2A
Limit: Max 8h
Max 8h
Max 20h
Max 10h
3 minutes
30 min or 4h
depending on
battery voltage
10 days
Charge cycle
restarts if voltage
drops
Charge cycle
restarts if voltage
drops