Analysis recond float pulse – CTEK XT 14000 User Manual
Page 7

GB • 7
Analysis
Recond
Float
Pulse
Tests whether the
battery retains
the energy
Reconditioning of
a drained battery
Maintenance for
maximum
performance
Maintenance for
maximum
battery life
Analysis
Recond
Float
Pulse
Warning indication if
voltage drops to 1.0V in
3 minutes.
Max 15.8V and 3A for
4h for deeply discharged
batteries. Otherwise
for 30 minutes (only in
Recond mode).
13.6V with max 5A for
max 10 days.
Pulse start at 1.9V, max
voltage 14.4V.
13.6V max 5A.
Analysis
Recond
Float
Pulse
Warning indication if
voltage drops to 1.0V in
3 minutes.
13.6V with max 5A for
max 10 days.
Pulse start at 1.9V, max
voltage 14.4V.
Analysis
Recond
Float
Pulse
Warning indication if
voltage drops to 4.0V in
3 minutes.
Max 31.6V and 1.7A for
4h for deeply discharged
batteries. Otherwise
for 30 minutes (only in
Recond mode).
7.V with max 14A for
max 10 days.
Pulse start at 5.8V, max
voltage 8.8V.
7.V max 14A.
Analysis
Recond
Float
Pulse
Warning indication if
voltage drops to 4.0V in
3 minutes.
7.V with max 14A for
max 10 days.
Pulse start at 5.8V, max
voltage 8.8V.