Keypad lockout, Spare, Block select a – CONTREX CX-1200 User Manual
Page 20
![background image](/manuals/334429/20/background.png)
Page 18
Figure 21 Keypad Lockout
ENABLE
8
9
J6
Com
DI_6
LOCKOUT
Figure 22 Spare
Spare
8
10
J6
Com
DI_7
Figure 23 Block Select A
Block Select A
1
3
J7
DI-8
Com
Keypad Lockout
(J6 pins 9, 8)
Digital Input 6
When the Keypad Lockout input is closed, the Control
Parameters that you have selected to "lock out" are
inaccessible from the front keypad. All of the Monitor
Parameters remain enabled.
Spare
(J6 pins 10, 8)
Digital Input 7
The Spare input is not defined at this time.
Block Select A
(J7 pins 1,3)
Digital Input 8
Block Select A is a maintained input. Close this input to
select "Block 1" as the active parameter block. When this
input is open, "Block 0" is the active block.