5 environmental requirements, 6 emc technical ratings, 7 emission specifications – Cleveland Motion Controls Classic Series DIN Rail Amplifier with Isolated Output MWI-13467 REV CA User Manual
Page 8: Nvironmental, Equirements, Echnical, Atings, Mission specifications, 6 emc
![background image](/manuals/333976/8/background.png)
C
LASSIC
S
ERIES
A
MPLIFIER W
/
I
SOLATED
O
UTPUTS
MAN-13467
REV
CA
Page 8 of 30
1.5 E
NVIRONMENTAL
R
EQUIREMENTS
Requirement
Description
Enclosure IP20
NEMA 1
Operating temperature
0 to 55 degrees C
32 to 132 degrees F
Humidity Non-condensing
85% at 55 degrees C
85% at 132 degrees F
Altitude 1000
meters
3300 feet
Atmosphere
Non-flammable, non-corrosive and dust free
Storage temperature range
-25 to 80 degrees C
-13 to 176 degrees F
Transport temperature range
-25 to 80 degrees C
-13 to 176 degrees F
1.6 EMC
T
ECHNICAL
R
ATINGS
Port
Phenomenon
Test Standard
Level
Test Standard
Enclosure
ESD
EN 61000-4-2
8KV AD, 1KV CD
EN 61326:1997
Enclosure
RF Field
EN 61000-4-3
10V/m,1 Khz AM
EN 61326:1997
Transducer Leads
Fast Transient
Burst
EN 61000-4-4
1kV
EN 61326:1997
Output Leads
Fast Transient
Burst
EN 61000-4-4
1kV
EN 61326:1997
Transducer Leads
Conducted
Immunity
EN 61000-4-6
3V/m
EN 61326:1997
Output Leads
Conducted
Immunity
EN 61000-4-6
3V/m
EN 61326:1997
** AC Power Line
Surge
EN 61000-4-5
+/-2KV L to PE
+/-1KV L to L
EN 61326:1997
** AC Power Line
Voltage Dips
EN 61000-4-11
+/-0.5 Cycle
100%
EN 61326:1997
** These specifications apply when using CMC power supply, MWI-13418.
1.7 E
MISSION SPECIFICATIONS
Port
Phenomenon
Test Standard
Level
Generic Standard
Enclosure Radiated
EN
61326:
1997
Class A
EN 61326:1997
The levels of performance indicated are achieved when the Classic Series DIN Rail Amplifier is