Make Smoke Bridge a Controller
1) Press and hold Smoke Bridge set button until it beeps
Smoke Bridge LED will start blinking green
You will have four minutes to complete the next steps before linking mode times out
2) Adjust responder to desired state
3) Press and hold responder set button until it double-beeps
Smoke Bridge will double-beep and its LED will stop blinking
4) To test, first change the responder to a different state then the desired state
5) Test by tapping Smoke Bridge set button
The Set button will cycle through the following notifications with a brief delay between each
- Smoke detected
- Carbon Monoxide (CO) detected
- Low Battery detected
- Error
- All Clear
Smoke Bridge LED will blink red during these steps
~15 seconds after it sends the All Clear command, it will turn solid green
Responder will respond appropriately
Scenes
Devices in a scene can each have different settings. This provides for advanced scene creation. Software
is recommended for scene management.
Example of a scene with Smoke Bridge as a Controller:
1) Press and hold Smoke Bridge set button until it beeps
Smoke Bridge LED will start blinking green
2) Tap Smoke Bridge set button
Smoke Bridge LED will start double-blinking green
3) For each scene member:
a. Adjust member to desired scene state
b. Press and hold Set button until it double-beeps
4) Tap Smoke Bridge set button
Smoke Bridge will beep and LED will stop blinking
5) To test, first change the responder to a different state then the desired state
6) Test by tapping Smoke Bridge set button
The Set button will cycle through the following notifications with a brief delay between each
- Smoke detected
- Carbon Monoxide (CO) detected
- Low Battery detected
- Error
- All Clear
Smoke Bridge LED will blink red during these steps
1
If responder is a multi-scene device such as a KeypadLinc, tap scene button you wish to control until the LED is in the desired scene state (on or off).
2
If either controller or responder LED continues blinking, the addition failed. Tap device’s Set button until LED stops blinking and try linking again.