Problem
Possible Cause
Solution
Smoke Bridge can
turn off a Responder,
rather than on.
The responder may be
linked at its off state.
Re-Link the responder to smoke bridge, while the
responder’s load is on. See the Responder’s
Owner’s Manual for more detailed linking
instructions.
When I press Test on
smoke alarm, the
Smoke Bridge
responders are not
turning on.
Using the Set button to
create a link to a
responder links it to the
Smoke Detected group
only.
To link to the test button group, you must use
software or a smart device (iOS or Android) app.
Smoke Bridge is
locked up.
A surge or excessive
noise on the power line
may have glitched it.
Unplug Smoke Bridge for 10 seconds and then
reinstall.
If the above doesn’t work, perform a factory reset.
See
Resetting Smoke Bridge to its Factory Default
If you have tried these solutions, reviewed this Owner’s Manual, and still cannot resolve an issue you are
having with Smoke Bridge, please call:
INSTEON Support Line
866-243-8022