Programming
Prior Service Volume Used Display (E)
Press the Program button. This displays the amount of water treated since the last system flush recorded.
The unit of measurement used is gallons/liters/cubic meters.
Example: 850 Gallons - [ E - - - 850]
Previous Days Water Usage Display (Pd)
Press the Program button. This displays the previous days water usage in gallons/liters/cubic meters.
Example: 200 gallons - [ P d - - 200 ]
Timed Auxiliary Output Window #1 Setting (y)
This setting should be set to OFF.
Cancel setting
[ y - - - OFF]
Timed Auxiliary Output Window #2 Setting (r)
This setting should be set to OFF.
Cancel setting
[ r - - - OFF]
Chemical Pump Output (n)
This setting should be set to OFF.
Cancel setting
[ n - - - OFF]
US/Metric Display Format (U)
Press the Program button. This display is used to set the US or Metric format.
There are five possible settings:
1. The
U.S. Format uses gallons for volume and gallons per minute for flow rate related data/displays with a
12-hour timekeeping format.
Example: [U - - - - - 1 ]
2. The
European Metric Format uses liters for volume and liters per minute for flow rate related data/displays
with a 24 hour timekeeping format.
Example: [U - - - - - 2 ]
3. The
Standard Metric Format uses liters for volume and liters per minute for flow rate related data/displays
with a 24 hour timekeeping format.
Example: [U - - - - - 3 ]
4. The
Cubic Meter Metric Format uses m3 for volume and liters per minute for flow rate related data/
displays with a 24 hour timekeeping format.
Example: [U - - - - - 4 ]
5. The
Japanese Metric Format uses liters for volume and liters per minute for flow rate related data/displays
with a 24 hour timekeeping format.
Example: [U - - - - - 5 ]
— Use the Set Up and Set Down buttons to adjust these settings.
Regeneration Type (7)
Press the Program button. This display is used to set the type of flushing initiation. The default setting of
meter immediate is highly recommended for proper flushing and operation of the FreshPoint™ system.
6.
7.
8.
9.
10.
11.
12.