Programming – Hydrotech FreshPoint U440 Ultrafiltration System User Manual
Page 24

Page 24
Programming
Example:
12:59 A.M.
(System in Service)
Example:
125 Gallons of Water
Remaining
(System in Service)
(No Water Flow)
Example:
0 Gallons of Water
Remaining
(System in Service)
(Water Flowing, Meter
Arrow Flashing)
Example:
(System is sending
0.5 minute regen signal)
(Regeneration Arrow)
Regeneration
Signal
Controller Operation During Service
1. In normal operation the Time of Day and Volume Remaining displays will alternate. Set the
Time of Day display by pressing the Set Up or Set Down buttons to the correct time.
2. The Volume Remaining display is the volume of water (in gallons) remaining prior to flushing. Without
any water usage, the Meter Arrow should be either off or on but not changing. Open a tap. The Meter Arrow
should begin flashing at a rate that varies with flow rate. Close the tap after 3-5 gallons of water flow.
Timer Operation During a Flush Cycle
1. Manually initiate a flush cycle and allow water to run to the drain. To initiate a flush, press and release the
Extra Cycle button. The system will go into flush mode immediately.
A.
During Flushing: The the system will display the time remaining.
B. Pushing the Set Up or Set Down button during the flush cycle will adjust the time remaining in that cycle.
The programmed flushing time will not be changed.
C. After the flush cycle, the system returns to in service and will resume normal operation.