beautypg.com

Specifications – Hydra-Flex Aqua-Lab MD Operating Manual User Manual

Page 3

background image

Operating Manual

© Hydra-Flex Inc 2011

- 3 -

Specifications

1.

Operating water pressure: 200 psi (Factory set)

2.

Pneumatics operating pressure: 100 psi (Factory set)

3.

Maximum water source temperature 140° F

4.

Operating ambient temperature: 40-120° F

5.

Electrical supply

a. 208/230 or 480 volts (3-phase)
b. 3 hp pump 11.5 amps @ 230 volts or 5.8 amps @ 480 volts
c. Overload Setting 12.0 @ 230 volts or 6.0 @ 480 volts

6.

Operate solenoid valves with 24VAC, 24VDC, 120VAC

a. 1.5 amp per port

7.

Water supply

a. 1.5” ID line dual operating pump feed
b. 1” ID Line single operating pump feed
c. Inlet pressure: 2-80 psi

i. If pumps are fed from tank, water level must be 54” above pumps.

8. Air supply

a. 3/8” feed per system
b. 20 CFM @ 100 psi supply

9. Solution lines

a. ½” poly lines (3/4” for high flow applications such as rain bars)

10. Space requirements:

a. AQUA-LAB Systems

i. MD5 model – 2’ wide x 2.5’ high of wall space

ii. BX model – 2’ wide x 2.5’ high of wall space

b. Pump assemblies – pumps need to be within 6’ of the system to allow connection with the connection

hose included (longer connections can be run with customer supplied hose)

i. Single pump wall mount – 4’ x 3’ wall space

ii. Triple pump wall mount – 4’ x 4’ of wall space

c. Electrical enclosures

i. Motor starter – 1.5’ wide x 1.5’ high of wall space

ii. Terminal box (accessory) – 1’ wide x 1’ high of wall space








For Additional Support Call:

952.808.3640