beautypg.com

Introduction, Specifications, Compatibility – GxT Ferret 925 Amp Probe User Manual

Page 2

background image

Introduction

The Probe is a clamp-on AC/DC current probe for use with common digital
multimeters and labscopes. It has been designed and tested according to IEC
Publication 1010-2-032 (1994, 12) (Overvoltage Category III), Safety Requirements
for Hand-help Current Clamps for Electrical Measurement and Test, the EMC
Directive (EN 50081-1 and EN 50082-1). Designed to Protection Class II, Double
or reinforced insulation requirements of UL 3111, CAN/CSA C22.2 No. 1010.1-
92, ISA-DC82, and IEC 1010-2-032.

Specifications

Current Ranges:

0-1 to 400A AC/DC and 1A to 1000A dc/ac

Output Signals:

1mV per Amp AC/DC in the 400 Amp range
0.1mV per Amp AC/DC in the 1000 Amp range

Accuracy: (DC to 400Hz)

±

(2% of reading + 5)

Working Voltage:

600V AC/DC rms

Common Mode Voltage:

42V DC or 30V AC

Storage Temperature:

-20

°

C to 60

°

C (-4

°

F to 140

°

F)

Operating Temperature:

0

°

C to 45

°

C (32

°

F to 95

°

F)

Relative Humidity:

0% to 80% (0

°

C to 35

°

C; 32

°

F to 113

°

F)

0% to 70% (35

°

C to 45

°

C; 95

°

F to 113

°

F)

Battery Type:

9V, NEDA 1604 or IEC 6LR61

Battery Life:

200 Hours typical (alkaline)

Max. Conductor Size:

1 Conductor 51mm (2.00 inch)
2 Conductor 25mm (.98 inch)

Maximum Jaw Opening:

52mm (2.04 inc.)

Output Cable:

1.6 meters (63 inches)

Dimensions:

205 x 97 x 44mm (8.07 x 3,82 x 1.73 in.)

Weight:

410g (14.5 oz.)

Compatibility

The Probe is compatible with any 4000 count millivolt measuring device that has
the following features:

Range and resolution capable of displaying millivolts with a 1 millivolt resolution
for the 400 Amp range, and a resolution of 0.1 Millivolt for the 1000 Amp
range.

Accepts standard safety-shrouded plugs or a banana plug.

Input impedance of greater than or equal to 10M