Burkert Type 8030 User Manual
Page 5

16
Table 1: Dimension H [mm] of the 8030 depending on
the DN of fitting S030
dn
h with fitting
s030
H
06
95,5
08
95,5
15
100,5
20
98
25
98
32
102
40
105,5
50
112
65
112
32
40
66
44
54
9
Fig. 1:
Dimensions [mm] of the SE30 electronic
module
English
17
materials
Part
Material
Housing, male fixed
connector
PC
Female connector
type 2508 / screw /
seal
PA / Stainless steel / NBR
Fitting S030
refer to the operating instructions of the
fitting used.
electrical data
Supply voltage
• Hall version
• Hall Low Power
version
• 12-36 V DC, filtered and
regulated
• 12-36 V DC, via transmitter
the device is connected to
Dielectric strength
2300 VAC
Current consumption
• Hall version
• Hall Low Power
version
• 30 mA max.
• 0,8 mA max.
Protection against
polarity reversal
yes
English
17
18
Protection against spike
voltages
yes
Protection against short
circuits
yes
Transistor output (Hall
version)
pulse output, NPN and PNP,
open collector, max. 100 mA,
frequency up to 300 Hz, duty
cycle 1/2 ±10%
NPN output: 0,2-36 VDC
PNP output: supply voltage
Transistor output (Hall
Low Power version)
pulse output, NPN, open
collector, max. 10 mA,
frequency up to 300 Hz, duty
cycle 1/2 ±10%
electrical connection
type of connector
cable type
female connector
type 2508 (supplied),
ordering code 438811
• shielded, max. 50 m
• 5 to 8 mm in diameter
• wires between 0,25 and
1,5 mm
2
in cross section
English
19
7. insTAllATion AnD
commissioninG
safety instructions
danger
risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure
and drain the pipe before loosening the process
connections.
risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid and drain the pipe before
loosening the process connections.
risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident pre-
vention and safety relating to the use of hazardous
products.
English
19