SPECIFICA TIONS

Step Two

Supply voltage:

14-36 VDC (type 8622-D..)
120 / 240 VAC, 50 - 60 Hz. (type 8622-A..)

Consumption:

.25 amps

Sensor supply:

13.5 VDC @ 100 mA

Relay type:

Isolated single pole double throw (SPDT)

relay,

Form C

Relay load:

Switching voltage
240 VAC/150VDC max. (8622-D..)
380 VAC/150VDC max. (8622-A..)
Switching current
6 Amps (non inductive load) (8622-D..)
12 Amps (non inductive load) (8622-A..

)

Relay mode:

Selectable, NO or NC

Time delay:

0 to 60 seconds

LED indication:

Sensor, relay & power status

Fail safety:

Power fail-safe

Enclosure rating:

NEMA 4X / IP65

Enclosure material: Polypropylene (U.L. 94 VO)
Enclosure rotation: 300

°

swivel base

Temperature range:F: -40

°

to 158

°

C: -40

°

to 70

°

Conduit connection:1/2" NPT

Make a Fail-Safe System:

Design a fail-safe system that accommodates the possibility of relay or power failure. If power is cut off to the controller, it will de-energize the relay. Make sure
that the de-energized state of the relay is the safe state in your process. For example, if controller power is lost, a pump filling a tank will turn off if it is connected
to the Normally Open side of the relay.

While the internal relay is reliable, over the course of time relay failure is possible in two modes: under a heavy load the contacts may be “welded” or stuck into
the energized position, or corrosion may build up on a contact so that it will not complete the circuit when it should. In critical applications, redundant backup
systems and alarms must be used in addition to the primary system. Such backup systems should use different sensor technologies where possible.

While this manual offers some examples and suggestions to help explain the operation of Bürkert products, such examples are for information only and are not
intended as a complete guide to installing any specific system.

Dimensions

GND AC AC

R

P

DELAY

Rela

y

Com NO NC

I (ON/OFF)

L (ON/OFF)

Relay LED

(red)

Input A LED

(amber)

Input

Terminal

Delay

Power LED

(green)

Invert

Relay

Terminal

AC Input

STATUS

Delay

INVERT

- +

SENSOR

RELA

Y

PO

WER

Faceplate Cover

(8622-A..):

AC version

(8622-D..):
DC version

120 VAC, 50-60 Hz, 0.25 Amp.
240 VAC, 50-60 Hz, 0.25 Amp.

Always replace this safety cover after service

Model: 8622-A..
S/N: XXXXXX

Power supply
120/240 VAC,50-60 Hz,
0.25 Amps
Maximum relay Rating
250 VAc, 12 A, 1/2 Hp

DELAY

Side wiew
DC version:

Invert Switch

Delay

Relay

- +

Input

Terminals

NC

Com

NO

DC

Power Input

Relay

Terminal

Invert

Delay

Relay

Latch/ Invert Logic

Time Delay

Sensor

Input 1

Power
Supply

NC

NO

C

(+)

(-)

S

AC

AC

GND

Top wiew
AC version:

Relay

Latch/ Invert Logic

Time Delay

Sensor

Input 1

Power
Supply

NC

NO

C

(+)

(-)

S

DC

DC

DC version

AC version

120

mm

81.7

mm

25.5

mm

17.8

mm

71.5

mm

F L O W L I N E

F L O W L I N E

95

mm

56.7

mm

25.5

mm

17.8

mm

71.5

mm

F L O W L I N E

F L O W L I N E