beautypg.com

BJM Pumps SKX150CSSF-575T User Manual

Page 35

background image

START-UP REPORT FORM

Are guide rails vertical?

Yes

No

Is base elbow installed level?

Yes

No


Liquid level controls: Model

Is control installed away from turbulence?

Yes

No

Float Operation Check

Tip lowest float (stop float), all pumps should remain off.
Tip second float (and stop float), one pump comes on.
Tip third float (and stop float), both pumps on (alarm on simplex).
Tip fourth float (and stop float), high level alarm on (omit on simplex).

Check here if using manual on/off only.

Does liquid level ever drop below volute top?

Yes

No

Control Panel MFG & model no.

Number of pumps operated by control panel

NOTE: At no time should hole be made in top of control panel, unless proper sealing
devices are utilized.

Short Circuit protection:

Type:

Number and size of short circuit device(s)

Amp rating:

Overload type:

Size:

Amp rating:

Do protective devices comply with pump motor amp
rating?

Yes

No

Are all pump connections tight?

Yes

No

Is the interior of the panel dry?

Yes

No

If No, correct moisture problem.

Electrical readings

SINGLE PHASE

Voltage supply at panel line connection, pump off L1

L2

Voltage supply at panel line connection, pump on L1

L2

Amperage load connection, pump on

L1

L2

THREE PHASE

Voltage supply at panel line connection, pump off

L1-L2

L2-L3

L3-L1

Voltage supply at panel line connection, pump on