Trouble shooting, Pump will not run, Pump runs but does not deliver rated capacity – BJM Pumps SKX150CSSF-575T User Manual
Page 14
14
DO NOT PLACE HANDS IN PUMP SUCTION WHILE CHECKING
MOTOR ROTATION. TO DO SO WILL CAUSE SERVER PERSONAL INJURY.
Three phase pumps have integral motor overload protection. It is recommended that all
three phase pumps using a motor starting device also incorporate motor overload
protection. Pumps must be installed in accordance with the National Electrical Code
and all applicable local codes and ordinances. Pumps are not to be installed in locations
classified as hazardous in accordance with National Electrical Code, ANSI/NFPA 70.
Connect pump to a junction box, outlet box, control box, enclosure with a wiring
compartment that meets NEC and local codes. The provision for supply connection
shall reduce the risk of water entry during temporary, limited submersion and shall
comply with the applicable requirements of the Standard for Enclosures for Electrical
Equipment, UL 50, or the standard for Metallic Outlet Boxes, UL 514A, and the standard
for Motor-Operated Water Pumps. UL 778.
TROUBLE SHOOTING
Disconnect the power source to the pump BEFORE attempting
any type of trouble shooting, service or repair.
PUMP WILL NOT RUN
1. Check power supply (fuses, breaker). Reset power.
2. Blocked impeller. Remove strainer, check and clean.
3. Defective cable or incorrect wiring.
4. Strainer clogged. Check and clean as necessary.
5. Float switch tangled/obstructed. Clean and free float switch from obstruction.
6. Float switch defective. Replace float switch.
7. Pump overheated or temperature of liquid exceeds pump operating
temperature.
PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY
1. Discharge line clogged, restricted or hose kinked. Check discharge hose/pipe.
2. Worn impeller and/or suction cover. Inspect and replace as necessary.
3. Pump overloaded due to liquid pumped being too thick.
4. Pumping air. Check liquid level and position of pump.
5. Excessive voltage drops due to long cables.
6. Three phase only; pump running backwards, check rotation.