PUMP OPERATION
This pump is designed to handle dirty water that contains some solids. It is
not designed to pump volatile or flammable liquids. Do not attempt to pump any liquids which
may damage the pump or endanger personnel as a result of pump failure.
Do not operate this pump where explosive vapors or flammable
material exist. Death or Serious injury will result.
TYPICAL MANUAL WASTEWATER INSTALLATION
NOTE: Maximum recommended starts should not exceed 10 times per hour.
All S-F & SX-F models
are provided with a 33’ (10 m) power cord. NEVER splice the power
cable due to safety and warranty considerations. Always keep the lead end dry.
Note: 208V, 230V, 460V & 575V three phase units do not have a plug and have to be provided
separately.
Do not alter the length or repair any power cable with a splice. The pump
motor and cable must be completely waterproof. Damage to the pump or personal injury may
result from alterations.
For manual operation: 208, 230, 460 & 575 volt: Connect directly to the power source or
control box. Check the direction of the rotation. Tilt the pump and start it. It should twist in the
opposite direction of the arrow (on pump).
- SX75CSSF-460T SX75CSSF-230T SX55CSSF-575T SX55CSSF-460T SX55CSSF-230T SX55CSSF-208T SX37CSSF-575T SX37CSSF-460T SX37CSSF-230T SX37CSSF-208T SX22CSSF-575T SX22CSSF-460T SX22CSSF-230T SX22CSSF-208T SX15CSSF-575T SX15CSSF-460T SX15CSSF-230T SX15CSSF-208T SX1500CSSF-230 SX750CSSF-230 SX750CSSF-115 SX08CSSF-575T SX08CSSF-460T SX08CSSF-230T SX08CSSF-208T S75CF-575T S75CF-460T S75CF-230T S55CF-575T S55CF-460T S55CF-230T S55CF-208T