BJM Pumps SX75CSSF-575T User Manual
Page 29

START-UP REPORT FORM
Are guide rails vertical?
Yes
No
Is base elbow installed level?
Yes
No
Liquid level controls: Model
Is control installed away from turbulence?
Yes
No
Float Operation Check
Tip lowest float (stop float), all pumps should remain off.
Tip second float (and stop float), one pump comes on.
Tip third float (and stop float), both pumps on (alarm on simplex).
Tip fourth float (and stop float), high level alarm on (omit on simplex).
Check here if using manual on/off only.
Does liquid level ever drop below volute top?
Yes
No
Control Panel MFG & model no.
Number of pumps operated by control panel
NOTE: At no time should hole be made in top of control panel, unless proper sealing
devices are utilized.
Short Circuit protection:
Type:
Number and size of short circuit device(s)
Amp rating:
Overload type:
Size:
Amp rating:
Do protective devices comply with pump motor amp
rating?
Yes
No
Are all pump connections tight?
Yes
No
Is the interior of the panel dry?
Yes
No
If No, correct moisture problem.
Electrical readings
SINGLE PHASE
Voltage supply at panel line connection, pump off L1
L2
Voltage supply at panel line connection, pump on L1
L2
Amperage load connection, pump on
L1
L2
THREE PHASE
Voltage supply at panel line connection, pump off
L1-L2
L2-L3
L3-L1
Voltage supply at panel line connection, pump on
- SX75CSSF-460T SX75CSSF-230T SX55CSSF-575T SX55CSSF-460T SX55CSSF-230T SX55CSSF-208T SX37CSSF-575T SX37CSSF-460T SX37CSSF-230T SX37CSSF-208T SX22CSSF-575T SX22CSSF-460T SX22CSSF-230T SX22CSSF-208T SX15CSSF-575T SX15CSSF-460T SX15CSSF-230T SX15CSSF-208T SX1500CSSF-230 SX750CSSF-230 SX750CSSF-115 SX08CSSF-575T SX08CSSF-460T SX08CSSF-230T SX08CSSF-208T S75CF-575T S75CF-460T S75CF-230T S55CF-575T S55CF-460T S55CF-230T S55CF-208T