Pre-installation inspection, Oil fill quantity/type – BJM Pumps SX75CSSF-575T User Manual
Page 6
6
The following are recommended installation practices/procedures for the pump. If there are
questions in regards to your specific application, contact your local BJM Pumps distributor or
BJM Pumps, LLC.
PRE-INSTALLATION INSPECTION
1) Check the pump for damage that may have occurred during shipment.
2) Inspect the pump for any cracks, dents, damaged threads, etc.
3) Check power cord and sensor cable for any cuts or damage.
4) Check for, and tighten any hardware that appears loose.
5) Carefully read all tags, decals and markings on the pump.
6) Important: Always verify that the pump nameplate, amps, voltage, phase, and HP
ratings match your control panel and power supply.
Warranty does not cover damage caused by connecting pumps and controls to an incorrect
power source (voltage/phase supply). Record the model numbers and serial numbers from the
pumps and control panel on the front of this instruction manual for future reference. Give it to
the owner or affix it to the control panel when finished with the installation.
If anything appears to be abnormal, contact your BJM Pumps distributor or BJM Pumps, LLC.
If damaged, the pump may need to be repaired before use. Do not install or use the pump until
appropriate action has been taken.
Lubrication:
No additional lubrication is necessary. The shaft seal and bearings are fully lubricated from the
factory. Seal oil should be checked once per year. See table below.
OIL FILL QUANTITY/TYPE
OIL IN SEAL CHAMBER
MODEL
U.S. FL. OZ.
CC.
TYPE OF OIL
S08C-F
7.8
230 ISO 32 NSF Food Grade Mineral Oil
S15C-F
7.8
230 ISO 32 NSF Food Grade Mineral Oil
S22C-F
11.8
350 ISO 32 NSF Food Grade Mineral Oil
S37C-F
11.8
350 ISO 32 NSF Food Grade Mineral Oil
S55C-F
35.5 1050 ISO 32 NSF Food Grade Mineral Oil
S75C-F
35.5 1050 ISO 32 NSF Food Grade Mineral Oil
OIL IN SEAL CHAMBER
MODEL
U.S. FL. OZ.
CC.
TYPE OF OIL
SX08CSS-F
10.1
300 ISO 32 NSF Food Grade Mineral Oil
SX15CSS-F
10.1
300 ISO 32 NSF Food Grade Mineral Oil
SX22CSS-F
13.5
400 ISO 32 NSF Food Grade Mineral Oil
SX37CSS-F
13.5
400 ISO 32 NSF Food Grade Mineral Oil
SX55CSS-F
35.5 1050 ISO 32 NSF Food Grade Mineral Oil
SX75CSS-F
35.5 1050 ISO 32 NSF Food Grade Mineral Oil
NOTE: The stator on this model is oil filled. This needs to be changed annually when the seal oil is
changed. With the power cable entry removed, fill the motor chamber with oil to a level that insures the oil
is covering the motor windings by ½”, and that will be above the upper bearing. Do not overfill, an air gap
of 10-15% must be maintained for heat expansion.
- SX75CSSF-460T SX75CSSF-230T SX55CSSF-575T SX55CSSF-460T SX55CSSF-230T SX55CSSF-208T SX37CSSF-575T SX37CSSF-460T SX37CSSF-230T SX37CSSF-208T SX22CSSF-575T SX22CSSF-460T SX22CSSF-230T SX22CSSF-208T SX15CSSF-575T SX15CSSF-460T SX15CSSF-230T SX15CSSF-208T SX1500CSSF-230 SX750CSSF-230 SX750CSSF-115 SX08CSSF-575T SX08CSSF-460T SX08CSSF-230T SX08CSSF-208T S75CF-575T S75CF-460T S75CF-230T S55CF-575T S55CF-460T S55CF-230T S55CF-208T