PUMP OPERATION

This pump is designed to handle dirty water that contains some

solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump
any liquids which may damage the pump or endanger personnel as a result of pump
failure.

Do not operate this pump where explosive vapors or

flammable material exist. Death or Serious injury may result.

NOTE: Maximum recommended starts should not exceed 10 times per hour.


All J-F & JX-F models are provided with a

50’ (15m) power cable. NEVER

UU

splice the

power cable due to safety and warranty considerations. Always keep the lead end dry.

Note: The single phase 115V and 230V high temperature pumps are designed to be
connected directly to a proper pump control and cannot be directly plugged into a power
outlet.

Do not alter the length or repair any power cable with a splice. The

pump motor and cable must be completely waterproof. Damage to the pump or
personal injury may result from alterations.

The BJM Pumps, J-F and JX-F series pumps require a special control that contains the
starting components, thermal sensor and Seal Minder connections. These pumps
cannot be directly connected to a power source.