2) Pump fails to run, or runs but fails to reach full speed.

Voltage drop in power line

Check whether or not the power voltage is normal

Single-phase run

Power switch, operation switch or pump cable

with either one wire opened or disconnected.

Inspect and repair or replace.

Stuck impeller

Repair

Motor trouble

Causes: Insulation fault, interlayer and interphase

short-circuit, single-phase disconnection

Inspect and repair.

3) Pump runs at full speed, but produces abnormal noise mechanically.

Broken impeller

Replace

Worn or damage bearing

Replace

Low level running

Not harmful, but less pumping rate and low

efficiency, caused by low suction level. Raise

suction level or stop the pump

4) Small pumping rate (capacity)

Reverse rotation of pump

Interchange two wires of the cable

for correct rotational direction

Impeller clogged with foreign matter

Remove foreign matter

Clogged pipe

Repair

Small size pipe

Replace

Water leakage from pipeline and channel

Inspect and repair

5) Motor overheated

Overload

Large mixture percentage of solids

to pumping water or use of liquids

with high viscosity or high specific

gravity.

Motor exposed to atmosphere

Consider of the pump location and

adjust or relocate.

Motor abnormal

Inspect insulation fault, interlayer

short-circuit and interphase short-

circuit.

In this event, the over current relay

of the operation switch might work.

If failed to work, check whether the

relay is properly set. In many cases,

motor abnormal is primarily caused

by its insulation down by leaked

water in section 7.