PUMP OPERATION
This pump is designed to handle dirty water that contains some
solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump
any liquids which may damage the pump or endanger personnel as a result of pump
failure.
Do not operate this pump where explosive vapors or
flammable material exist. Death or Serious injury will result.
TYPICAL MANUAL DEWATERING INSTALLATION
NOTE: Maximum recommended starts should not exceed 10 times per hour.
All KB models are provided with a 50
’ (10m) power cord.
U
NEVER
U
splice the power cable
due to safety and warranty considerations. Always keep the plug end dry.
Note: 230V, 460V & 575V three phase units do not have a plug and have to be
provided separately.
Do not alter the length or repair any power cable with a splice. The
pump motor and cable must be completely waterproof. Damage to the pump or
personal injury may result from alterations.
For manual operation: 230, 460 & 575 volt: Attach the proper plug or connect directly to
the power source or control box. Check the direction of the rotation. Tilt the pump and
start it. It should twist in the opposite direction of the arrow (on pump). It is
recommended that a Ground Fault Interrupter (GFI) type receptacle (or equivalent) be
used.
STOPPING
To stop the pump (manual and automatic mode), disconnect it from the power source,
turn off the breaker, or turn the power source off (generator).
Typical 3 phase manual control 1