beautypg.com

Pump installation, Positioning the pump – BJM Pumps JX SERIES SIDE DISCHARGE Electric Submersible Pumps User Manual

Page 8

background image

8

PUMP INSTALLATION


J & JX Series pumps have been evaluated for use with water or water based solutions.
Please contact the manufacturer for additional information.

Risk of electric shock. Pump models; J400, JX400, J750 &

JX750 (115v) are supplied with a grounding conductor and grounding-type attachment
plug. Pump models 230V single phase pumps and all three phase pumps do not come
with electric plug connectors. To reduce the risk of electric shock, be certain that it is
connected only to a properly grounded, grounding-type receptacle.

Lifting:

Attach a rope or lifting chain (not included) to the handle (or lifting rings) on the top of
the pump.

Do not lift the pump by the power cable or discharge hose/piping.

Proper lifting equipment (rope/chain) must be used.

POSITIONING THE PUMP


BJM Pumps
, J & JX Series pumps are designed to operate fully or partially submerged.
Do not run the pump dry. Refer to data sheet for minimum submersion depth for your
particular model. Data sheets can be obtained online at

HHUU

www.bjmpumps.com

UUHH

or by

calling BJM Pumps, LLC at 860-399-5937. As a general rule, J and JX Series side
discharge pumps can pump down to a level above the suction screen. Pumping lower
than screen will permit air to enter the pump and cavitate, lose prime or become air
bound.

Do not run the pump dry.

Pump liquid should not exceed a maximum temperature of 104°F.

Never place the pump on loose or soft ground. The pump may sink, preventing

water from reaching the impeller. Place on a solid surface or suspend the pump
with a lifting rope/chain. The J & JX Series pumps are provided with a suction
strainer to prevent large solids from clogging the impeller. Any spherical solids
which pass through the strainer should pass through the pump.

For maximum pumping capacity, use the proper size non-collapsible hose or rigid

piping. A check valve may be installed after the discharge to prevent back flow
when the pump is shut off.


This manual is related to the following products: