Typical automatic dewatering-effluent installation – BJM Pumps JX SERIES SIDE DISCHARGE Electric Submersible Pumps User Manual
Page 11
11
Single phase pumps always use a three-prong grounded
receptacle. It is recommended that a Ground Fault Interrupter (GFI) type receptacle (or
equivalent) be used.
STOPPING
To stop the pump (manual and automatic mode), unplug it from the power source, turn
off the breaker, or turn the power source off (generator).
TYPICAL AUTOMATIC DEWATERING-EFFLUENT INSTALLATION
NOTE: Maximum recommended starts should not exceed 10 times per hour.
Float switches (wired into the pump motor or piggy-back style) are available from the
factory as an option.
Note: 208, 230V 460V & 575V pumps do not have a plug installed.
Three phase pumps need a separate control box with float(s) for automatic
operation.