PUMP OPERATION

This pump is designed to handle dirty water that contains some

solids. It is not designed to pump volatile or flammable liquids. Do not attempt to pump
any liquids which may damage the pump or endanger personnel as a result of pump
failure.

Do not operate this pump where explosive vapors or

flammable material exist. Death or Serious injury will result.

TYPICAL MANUAL DEWATERING-EFFLUENT INSTALLATION

NOTE: Maximum recommended starts should not exceed 10 times per hour.

All J & JX

models are provided with a 33” (10m) power cord (exception; J1500, JX1500,

J1500H

) are supplied with a 50’ (15m) power cord.

UU

NEVER

UU

splice the power cable due

to safety and warranty considerations. Always keep the plug end dry.

Note: 230V, single phase and 208V, 230V, 460V & 575V three phase units do not
have a plug and have to be provided separately.

Do not alter the length or repair any power cable with a splice. The

pump motor and cable must be completely waterproof. Damage to the pump or
personal injury may result from alterations.

For manual operation: 115 volt: plug the power cable into any 115 volt grounded
receptacle. 208, 230, 460 & 575 volt: Attach the proper plug, connect directly to the
power source or control box. Check the direction of the rotation. Tilt the pump and start
it. It should twist in the opposite direction of the arrow (on pump). It is recommended
that a Ground Fault Interrupter (GFI) type receptacle (or equivalent) be used.