Flowline LU78 EchoSwitch User Manual
Page 2
2 of 34
MN300282
Rev A
INTRODUCTION / TABLE OF CONTENTS
Step One
The EchoSwitch® is a general‐purpose ultrasonic level switch that provides the end user the ability to control
up to three unique devices (pump, valves and/or alarms) through an advanced non‐contact technology.
EchoSwitch® features push button configuration that uses real engineering values for setting up the relay
operation(s). One relay has SPDT Form “C” contacts useful for controlling a valve and the other two relays are
SPST Form “A”. All of the relays can be used for controlling valves, pumps or alarms.
Features
Simple digital push button configuration.
Pump simplex, duplex and triplex option.
Integrated timer for pump / valve delay and pump alternation.
Available in a 3m (9.8’), 5.5m (18.0’) or 8m (26.2’) maximum range.
Isolated 4/20 mA loop output for indicating level.
AC powered
Table of Contents
Specifications: ......................................................................................................................................................... 3
Dimensions:............................................................................................................................................................. 3
Safety Precautions: ................................................................................................................................................. 4
Getting Started: ....................................................................................................................................................... 6
TOP‐LEVEL MENU descriptions: ................................................................................................................. 7
Configuration: ...................................................................................................................................................... 10
How to Enter/Exit the TOP‐LEVEL MENU: ............................................................................................... 10
How to Configure UNITS: ......................................................................................................................... 10
How to Configure the Operational Range of EchoSwitch®: ..................................................................... 11
How to Set a HIGH ALARM: ...................................................................................................................... 12
How to Set a LOW ALARM: ...................................................................................................................... 13
How to Set a PUMP to FILL: ..................................................................................................................... 14
How to Set a PUMP to EMPTY: . ............................................................................................................... 15
How to Set a VALVE to FILL: ..................................................................................................................... 16
How to Set a VALVE to EMPTY: ................................................................................................................ 17
How to Select Fail‐Safe Output / LOST: ................................................................................................... 18
How to Duplex Two Relays: ..................................................................................................................... 19
How to Alternate Two Relays: ................................................................................................................. 20
How to Triplex Three Relays: ................................................................................................................... 21
How to Turn Off M‐PLEX (DUPLEX or TRIPLEX): ....................................................................................... 21
How to Time Alternate Relays: ................................................................................................................ 22
Electrical: .............................................................................................................................................................. 23
Input Power and Relay Connections: ....................................................................................................... 23
Analog Output (4/20 mA): ....................................................................................................................... 24
Wiring to Common Flowline Displays/Controllers: .............................................................................................. 25
Installation: .......................................................................................................................................................... 26
Mounting Guide: ...................................................................................................................................... 26
Installation in Existing Fittings: ................................................................................................................ 27
Appendix: ............................................................................................................................................................. 30
Troubleshooting: ...................................................................................................................................... 32
Warranty: ............................................................................................................................................................. 34