beautypg.com

Flowline LV55 FloaTek User Manual

Page 7

background image

17 SEPT 08

Float-Tek LV55 Series

7 of 12

Rev A

MN201345

Installation
FLOWLINE’s Float-Tek level switch is an in tank system. Float-Tek may be installed through
the top wall of any tank or flange, using a standard 2” NPT tank adapter or blind flange. If the
top is not available, Flowline’s side mount bracket, LM50-1001, enables Float-Tek to be
installed directly to the side wall or lip of the tank.

Tank Adapter:

Flange Mounting:

Side Mount Bracket:

side wall installation shown


Thread Treatment (Sealing):
When threading metal threads into a metal coupling, pipe sealant or Teflon tape is recommended.
When threading a metal sensor into a metal coupling, the installer should use a suitable wrench
and tighten the threads 1-1/2 turns past hand tight.