Flowline LV55 FloaTek User Manual
Page 10

10 of 12
Float-Tek LV55 Series
17 SEPT 08
MN201345
Rev
A
Specifications
Range:
6” to 96” (15.2 cm to 2.4 m)
Standard lengths:
16”, 24”, 32”, 36”, 42” or 48”
Note: sensing length will be shorter than the stem length by 2.63". This is
the top dead band and the bottom dead band added together
Accuracy:
0.25” over span in water
Resolution: 5
mm
Specific gravity:
0.55 minimum
Orientation:
+/- 30° from vertical
Supply voltage:
10 to 30 VDC
Loop resistance:
600 Ohms @ 24 VDC
Signal Output:
2-wire: 4-20 mA output
Calibration: None,
fixed
Process Temp.:
-40°C to 85°C
-40°F to 185°F
Pressure:
200 psi (13.8 bar)
Enclosure rating:
NEMA 4X (IP65)
Encl. material:
PP, UL94VO
Guide & float mat’l.: 316 SS
Float dia. = 2.1”
Stem diameters = 0.5”OD
Process mount:
2” NPT
Conduit entrance:
Single, ½” NPT
Classification: General
purpose
Compliance:
CE