5. CVBS Out
When CVBS_Out open, cameras support analogue BNC output, the default is CLOSED.
6. Auto Iris
1).when IrisMode off, Iris open max always. When IrisMode on, Iris will work after the priority of shutter.
2).Voltage: Voltage is different for different iris. The recommended value is 64 ± 8 micro. If the voltage is
too low, image will be dark even flashing while too high, image will be overexposure
3) IrisOpenSpeed and IrisCloseSpeed: the speed of iris change, when image flash and it is no use by
adjusting voltage, adjust the IrisSpeed, the recommended speed value for IrisOpenSpeed is 52, and
IrisiCloseSpeed is 94.
eLine Technology
eLineTechnology.com