beautypg.com

DE DIETRICH AWHP MIT-IN iSystem User Manual

Page 29

background image

Code Faults

Cause
of the
fault

Description

Checking / solution

D19

SOL.COL.S.FAIL

SCU

Header sensor fault

Bad connection

Sensor fault

4

Contact the professional who takes

care of maintenance of the appliance

D20

SOL COM.FAIL

SCU

Interruption in communication between the SCU PCB and the solar control system

4

Contact the professional who takes care of maintenance of the appliance

D27

PCU COM. FAIL

SCU

Communication failure between the SCU and PCU PCBs

4

Contact the professional who takes care of maintenance of the appliance

D32

5 RESET:ON/OFF

SCU

5 resets done in less than an hour

4

Switch off heat pump and start up again

D37

TA-S SHORT-CIR

SCU

The Titan Active System® is short-circuited

4

Check that the connection cable between the SCU PCB and the anode is not short-

circuited

4

Check that the anode is not short-circuited

Remarks:

Domestic hot water production has stopped but can nonetheless be restarted using key
r

.

The tank is no longer protected.

If a tank without Titan Active System® is connected to the heat pump, check that the

TAS simulation connector (delivered in package AD212) is fitted to the sensor board.

D38

TA-S DISCONNEC

SCU

The Titan Active System® is on an open circuit

4

Check that the connection cable between the SCU PCB and the anode is not severed

4

Check that the anode is not broken

Remarks:

Domestic hot water production has stopped but can nonetheless be restarted using key
r

.

The tank is no longer protected.

If a tank without Titan Active System® is connected to the heat pump, check that the

TAS simulation connector (delivered in package AD212) is fitted to the sensor board.

D99

DEF.BAD PCU

SCU

The SCU software version does not recognise the PCU connected

4

Contact the professional who takes care of maintenance of the appliance

L33

FLOW FAIL.

The flow rate is lower than the threshold defined by the MIN.STOP.FLOW. parameter

4

Contact the professional who takes care of maintenance of the appliance

AWHP MIT-IN iSystem

5. Troubleshooting

09/01/13 - 300027618-001-02

28