DE DIETRICH 220 SHL User Manual
Page 10

DHW tank 220SHL
Maximum operating pressure
bar 10
Water content
l
220
Top up volume
l
85
Solar volume
l
135
Weight
Shipping weight (Foam coated domestic hot water tank) kg 109
Performances related to the boiler type
Gas fired floor-standing condensing boiler
(1)
10/15 kW
15 kW
25 kW
35 kW
Power exchanged
kW
15
15
28
32
Flow per hour (∆T = 35°C)
(2)
l/h
370
370
690
790
Specific flow (∆T = 30°C)
(3)
l/min
20
20
24
26
Draw-off capacity
(3)
l/10 mm
200
200
240
260
Q
p
: Primary flow rate
m
3
/h
0.45
0.45
0.80
1.00
(1) Depending on the country in which the boiler is installed
(2) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary circuit (heating water): 80 °C
(3) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Primary circuit (heating water): 80 °C - Calorifier temperature: 60 °C
Performances related to the boiler type
Floor-standing condensing oil boiler
(1)
18 kW
24 kW
30 kW
Power exchanged
kW
18
24
30
Flow per hour (∆T = 35°C)
(2)
l/h
440
590
740
Specific flow (∆T = 30°C)
(3)
l/min
21
24
25
Draw-off capacity
(3)
l/10 mm
210
240
260
Q
p
: Primary flow rate
m
3
/h
0.75
0.75
0.85
(1) Depending on the country in which the boiler is installed
(2) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary circuit (heating water): 80 °C
(3) Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Primary circuit (heating water): 80 °C - Calorifier temperature: 60 °C
3.3
Composition of the NF CESI solar systems packages (for France only)
Check the composition of the NF CESI solar system package against
the table below. The references and packages listed must be shown
on the invoice for the system sold by the installer.
A system is complete and functional according to the NF CESI mark
if all system references appear on the invoice. The system is
composed of the following elements:
4
A collector field with 1 or 2 solar collectors.
4
A boiler system (Modulens or OEnoviaGas Confort / OEnoviaFioul
Confort) + solar domestic hot water tank to which a solar station
is mounted in the factory, which includes a heating pump, an
expansion vessel and a Diemasol A / Oetrosol A control system.
4
The solar fluid that protects the installation from frost and
corrosion.
3. Description
220 SHL
9
18/10/2012 - 300028214-001-02