7. Technical characteristics
7 Technical characteristics
Conditions of use:
- Max. safety temperature: 95 °C
- Safety thermostat: 105 °C
WHE 2.24
WHE 2.24 FF
Nominal input power
kW
26.6
25.4
Nominal useful output
kW
24
23.6
Minimum useful output
kW
8.4
8.4
Maximum output
kW
24
23.6
Efficiency (80/60 °C)
%
90.1
92.9
Gas flow rate
Natural gas (Pmax)
m
3
/h
2.77
2.65
Natural gas (Pmin)
m
3
/h
0.97
0.96
Butane / Propane
Kg/h
2.08
1.99
Heating
Minimum output temperature
°C
35
35
Maximum output temperature
°C
80
80
Minimum operating pressure
bar
0.8
0.8
Maximum operating pressure
bar
3
3
Domestic hot water
Minimum output temperature
°C
35
35
Maximum output temperature
°C
60
60
Minimum operating pressure
bar
0.3
0.3
Maximum operating pressure
bar
10
10
Minimum flow
l/min
3
3
Specific flow at
∆t=30K
l/min
11.4
11.4
Combustion products circuit
Mass flue gas flow rate (min / max)
Kg/h
70/75
59/50
Flue gas temperature (min / max)
°C
84/124
98/135
Value CO
2
(min / max)
%
1.8/4.9
2.1/7.1
Maximum pressure at the flue gas nozzle
Pa
-
35
Gas connection
inch
R 3/4
R 3/4
Heating connection
inch
R 3/4
R 3/4
Domestic hot water connection
inch
R 1/2
R 1/2
Electrical connection
V/Hz
230/50
230/50
Electrical power
W
105
150
Expansion vessel capacity
l
8
8
Net weight (without water)
kg
34.7
40.8
Dimensions
mm
750 x 454 x 340
750 x 454 x 340
Insulation class
IP20
IPX4D