8. Troubleshooting
8.3 Incidents and solutions
The burner is not working:
`
Check the boiler thermostat settings.
`
Carry out the checks mentioned in the burner instructions.
`
Shutdown by the safety thermostat due to accidental
overheating:
• Boiler: Check that the safety thermostat has not triggered. To
restart the boiler, reset the safety thermostat. Remove the safety
thermostat hood and press the reset button with a screwdriver.
• Condenser: Check that the safety thermostat has not triggered:
- Unscrew the protection cap
- Press the resetting button of the burner
`
Carry out the start-up operations again. Call your fitter.
`
Check the circuit breaker
The burner is operating but the radiators are cold:
`
Bleed the radiators.
`
Checking the hydraulic pressure. The hydraulic pressure must
be a minimum of 0.8 bars. Adjust the pressure if necessary,
avoiding a sudden influx of cold water into the boiler when it is
hot.
If it is often necessary to top up the installation with water,
contact your fitter.
`
Check that the heating pumps are working correctly
`
Check the position of the 3 position switch.
Control panel B3: TEST-STB/
.
/
%
on
.
.
Control panel DIEMATIC-m3: AUTO/
!
/TEST STB on
AUTO.
Control panel K3: AUTO/
!
/TEST STB on AUTO
`
Check the settings on the boiler thermostat(s).