Part 1 - specifications, Description specification – Dynasonics 701_771C Series Insertion Ultrasonic Flow Meter User Manual
Page 9

Rev. 12/97 -8- D77X
Non-linearity (Accuracy)
?
2% Full Scale
Sensitivity
0.05% of Full Scale
Repeatability
?
0.2% of Full Scale
Response Time
5-50 seconds, user configured, to 90% of
value, step change in flow.
Security
Keypad lockout, access code enable
PART 1 - SPECIFICATIONS
Description
Specification
Liquid Requirements
25 ppm of 30 micron suspended solids or
bubbles minimum
Transducer to Transmitter Distance
(Std) 15 feet [ 4.6 meters ], flexible armored
conduit. (Opt) lengths to 300 feet [ 90
meters ]
Pipe Sizes
(Std.) 1½ - 120 inches [ 38 – 3050 mm ]
Pipe I.D.
Temperature
(Std) - 40
° to 180°F [ -40° to 82°C].
Housing Material
(Std) 316 ss, PVDF, Viton™, Teflon™
Mounting
(Std) 1½ MNPT, pipe saddle or female
threaded coupling required. (Opt) 1½ 150#
Approvals
(Opt) FM approval I.S., Class I, Div 1,
Groups A-G.
DT7 Insertion Probe