PART 1 - SPECIFICATIONS

Description

Specification

Power Requirements

(Std) 110/220 VAC 50/60 Hz

?

5%. (Opt)

100/200 VAC 50/60 Hz

?

5% and 12/24

VDC. Power consumption less than 12 VA.

Velocity

0.12 - 30 FPS [ 0.03 – 9.1 MPS]

Outputs

4-20 mA, 1000 Ohms max., Isolated.

12 Vdc pulse, 100

?

S duration, 10 Hz max,

pulses with totalizer increments

Two Relays, 5A @ 250VAC resistive, SPDT

Display

2 line x 20 character alphanumeric LCD,
back lit. Digit height 0.2 inches [ 5 mm]

6 digit rate, 8 digit totalizer (resettable)

Units:

Rate US [Metric]

Totalizer US [Metric]

User configured

FPS, GPM, GPH, ft.

3

/M, MGD, BPM, BPH,

BPD [ MPS, LPM, M

3

/hr, LPD ]

Gallons, barrels (crude oil) [ liters ]

Ambient Conditions

-22 to 160

°F [ - 30 to 70 °C], 0-95% relative

humidity, non-condensing.

Enclosure

NEMA 4X, [IP -65] Fiberglass w/SS
hardware.

11H x 9.25W x 5.5D inches

[280H x 235W x 140D mm]