Page 2

Analog Heavy-Duty Data Sheet

Version: 20130507

HEA VY DUT Y INCLI NO ME T E R

ANA LOG & RS 232 I NT ER F ACE

Technical Data

Electrical Data

Mechanical Data

Housing Material

Die-cast Aluminum Alloy

Potting Material

Polyurethane

Shock (EN 60068-2-27)*

100 g (half sine, 6 ms)

Vibration (EN 60068-2-6)*

1.5 mm (10 Hz to 58 Hz) &

20 g (58 Hz to 2000 Hz)

Weight

170 gm / 6 oz

1

R

L

< 500

Ω with 15V DC

* Further data available on request

** Inclinometers should be connected only to subsequent electronics whose power supplies comply with EN 50178

(Protective Low Voltage)

Model

INC-080

INC-360

Measurement Range

± 80°

360°

Number of Axes

2

1

Analog

Interface

Voltage

0.5 to 4.5 V , 0° = 2.5 V
Load ≥ 10 KΩ with 12 VDC

0.5 to 4.5 V , 0° = 0.5 V
Load ≥ 10 KΩ with 12 VDC

Current

4 mA to 20 mA , 0° = 12 mA
Load ≤ 270 Ω

1

4 mA to 20 mA , 0° = 4 mA
Load ≤ 270 Ω

1

Digital Interface

RS232 (ASCII Format)

Baud Rate

Max. 115200 Baud (Programmable)

Resolution

0.01°

Accuracy (T = -10 °C to +40 °C)*

0.1°

Sensor Response Time

10 ms (without filter)

Recommended Measurement

Rate

Up to 10 Hz

Supply Voltage**

10 to 30 V DC (Absolute Maximum Ratings)

Power Consumption

≤ 0.7 W

EMC

Emitted Interference: EN 61000-6-4

Noise Immunity: EN 61000-6-2

Connection

Connector Output, 8 Pin M12 male (A-coded)