BEI Sensors Heavy Duty Inclinometers User Manual
Page 2

Page 2
Analog Heavy-Duty Data Sheet
Version: 20130507
HEA VY DUT Y INCLI NO ME T E R
ANA LOG & RS 232 I NT ER F ACE
Technical Data
Electrical Data
Mechanical Data
Housing Material
Die-cast Aluminum Alloy
Potting Material
Polyurethane
Shock (EN 60068-2-27)*
100 g (half sine, 6 ms)
Vibration (EN 60068-2-6)*
1.5 mm (10 Hz to 58 Hz) &
20 g (58 Hz to 2000 Hz)
Weight
170 gm / 6 oz
1
R
L
< 500
Ω with 15V DC
* Further data available on request
** Inclinometers should be connected only to subsequent electronics whose power supplies comply with EN 50178
(Protective Low Voltage)
Model
INC-080
INC-360
Measurement Range
± 80°
360°
Number of Axes
2
1
Analog
Interface
Voltage
0.5 to 4.5 V , 0° = 2.5 V
Load ≥ 10 KΩ with 12 VDC
0.5 to 4.5 V , 0° = 0.5 V
Load ≥ 10 KΩ with 12 VDC
Current
4 mA to 20 mA , 0° = 12 mA
Load ≤ 270 Ω
1
4 mA to 20 mA , 0° = 4 mA
Load ≤ 270 Ω
1
Digital Interface
RS232 (ASCII Format)
Baud Rate
Max. 115200 Baud (Programmable)
Resolution
0.01°
Accuracy (T = -10 °C to +40 °C)*
0.1°
Sensor Response Time
10 ms (without filter)
Recommended Measurement
Rate
Up to 10 Hz
Supply Voltage**
10 to 30 V DC (Absolute Maximum Ratings)
Power Consumption
≤ 0.7 W
EMC
Emitted Interference: EN 61000-6-4
Noise Immunity: EN 61000-6-2
Connection
Connector Output, 8 Pin M12 male (A-coded)