BEI Sensors Heavy Duty Inclinometers User Manual
Page 2

Page 2
Datasheet_INC-360-1-S102-VH2-PM
Version 130710
HEA VY DUT Y INCLI NO MET E R 360°
SYNCHRONOUS S E RIAL I NT E RFA CE ( S SI)
Technical Data
Electrical Data
Model
INC 360
Measuring Range
360°
Number of Axes
1
Resolution
13 Bit (0.04°)
1
Accuracy
0.14°
Sensor Response Time
100ms ± 10%
1
Interface
Synchronous Serial Interface (SSI)
Current Consumption
<250mA at 5V DC, <100 mA at 10 V DC, <80 mA at 24 V DC
Power Consumption
below 1.5 W
Clock Input
Via opto-coupler
Data Output
Line-driver according to RS 422
Clock Frequency
100 kHz
– 2 MHz
Supply Voltage
4.5
– 30 V DC (absolute maximum ratings)
2
Turn on Time
< 1 s
EMC
Emitted interference: EN 61000-6-4
Noise immunity:
EN 61000-6-2
1) Changes in response time and Resolution on request
2) According EN 50178 (SELF)
Mechanical Data
Housing Material
Aluminum
Potting Material
PUR (Polyurethane)
Weight
170 g [6 oz]
Environmental Conditions
Operating Temperature
-40 °C to +85 °C [-40 °F to 185 °F]
Protection class (EN 60529)
IP 69K & IP68 (With Mating Counter Connector)
Shock (EN 60068-2-27)
100 g (half sine, 6 ms)
Vibration (EN 60068-2-6)
1.5 mm (10 Hz to 58 Hz)
20 g (58 Hz to 2000 Hz)