CANopen Industrial Datasheet
Version 20130503
INDUST RIAL I NCLI NOME T ER
CA NOPE N INT ERFA CE
MTBF Data
Failure Rate [FIT]
759
MTBF [Hours]
1,317,822
MTBF [Years]
150
The above mentioned data were calculated for electronics under the following conditions:
SNA: Non-mobile operation
Tu: 40°C - Mean component of ambient temperature
Zf: Continuous operation for 8760 h per year
Programmable Parameters
Resolution per 1°
The resolution parameter per 1° is used to program the desired
number (1°, 0.1° and 0.01°) of steps per 1°.
Preset Value
The Preset value is the desired position value, which should be
reached at a certain physical position of the axis. The position
value is set to the desired process value by the preset parameter.
Moving Avarage-Filter
This filter can be used to adjust the bandwidth of measuring
values to minimize the influence of vibration. Factory Setting:
Moving average filter activated for 20 subsequent readouts.
Digital Recursive Filter
This filter can be used for weighting the last measured value with
the last previous value. This is useful to suppress sudden peaks in
the angle measurement.
Transmission Rate
Adjustable - Min. 20 kBaud; Max. 1 MBaud
Factory Setting : 125 kBaud
Address (Node ID)
Adjustable from 1 to 127
Factory setting: Node ID=1