CANopen Industrial Datasheet
Version 20130503
INDUST RIAL I NCLI NOME T ER
CA NOPE N INT ERFA CE
Technical Data
Electrical Data
Model
INC-080
INC-360
Measurement Range
± 80°
360°
Number of Axes
2
1
Resolution
0.01°
Accuracy (T = -10 °C to +40 °C)*
0.1°
Sensor Response Time
10 ms (without filter)
Recommended Measurement Rate
Up to 10 Hz
Interface
CANopen (In Conformance to DS410)
Transceiver According ISO 11898,
Galvanically Isolated by Opto-Couplers
Transmission Rate
Adjustable: Max. 1 MBaud
(Factory Setting : 125 kBaud)
Addressing
Programmable Node-id from 1 to 127 (Factory Setting: 1)
Supply Voltage
10 to 30 VDC (Absolute Maximum Ratings)
Current Consumption
Max. 57 mA at 10 V DC; Max. 53 mA at 24 V DC
EMC
Emitted Interference: EN 61000-6-4
Noise Immunity: EN 61000-6-2
Connection
Connector Output, 5 Pin M12 male (A-coded)
Mechanical Data
Housing Material
Glass Fiber Reinforced PBT (Polybutylene Terephthalate)
Potting Material
Polyurethane
Shock (EN 60068-2-27)*
100 g (half sine, 6 ms)
Vibration (EN 60068-2-6)*
1.5 mm (10Hz to 58Hz) &
20 g (58 Hz to 2000 Hz)
Weight
75 gm / 3 oz
Environmental Conditions
Operating Temperature
-40 °C to +85 °C / -40 °F to 185 °F
Humidity
98 % Relative Humidity, Non-Condensing
Protection Class (EN 60529)
IP 69K (With Appropriate Counter Connector) , IP68, IP67
*further data available on request