beautypg.com

C-Squared CO Analyzer Manual User Manual

Carbon monoxide analyzer instruction manual

background image

C-Squared Inc. 1440 S State College Blvd, Unit 4L, Anaheim, CA 92806
Tel: (714) 999-2791, Fax: (714) 999-2928,

[email protected]

,

www.c-squaredinc.com

Introduction

The C-Squared CO Analyzer is designed to measure CO levels in the 1ppm to 100ppm range.
It can be used to measure the CO content to assure safety in gas mixes that may be
contaminated due to the introduction of CO from internal combustion engines or other pumping
devices where CO is a bi-product. The Analyzer is designed to be able to verify CO
concentration in cylinders as well as analyze closed spaces.

The C-Squared Analyzer has a digital display, an internally or externally mounted temperature
compensated sensor with a 1 year life expectancy. The power is supplied by three AAA 1.5
volt batteries providing an expected operation life of one year before replacement is required.

The case has an environmentally sealed, potentiometer, on/off switch, long life sensor and
digital panel meter. The Analyzer is water resistant and sealed to prevent moisture from
affecting the internal components.

The Analyzer is shipped in a high impact case that can be used for storage or other purposes.
The Analyzer is ready to use out of the box with no additional work other than checking on the
calibration with an appropriate calibration gas at 50 or 100ppm.

Controls

The C-Squared Carbon Monoxide Analyzer has a splash proof on/off switch. When the switch
is centered it is in the off position. When not in use, the switch should be in the off position to
conserve battery life. When the switch is in the up position it is on. When the switch is flipped
down the unit will remain in the off position.

When switched on, the analyzer’s display will indicate a CO reading. Please note that the
analyzer has been calibrated prior to shipping but it should be checked routinely (see
calibration section).

The low battery warning is a battery symbol in the left corner of the display. When present
change the batteries prior to using the analyzer.

The display has a 1 ppm resolution and is sealed.

Incorporated

Carbon Monoxide Analyzer

Instruction Manual